ECI3808 Network Motion Control Card User Manual V1.5
3.4.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please select ETHERNET or RS232 (default parameter, which can
be connected directly) to connect to ZDevelop.
(3)
State values of relative input ports can be read directly through “IN” c
ommand, also,
it can be read through “ZDevelop/View/In”. Please refer to “ZBasic” for details.
(4)
Latch function can be set and triggered through “REGIST” instruction, in software, use
REG_INPUTS to configure. Please refer to “ZBasic” for details.
3.5.
OUT: Digital Output & PWM Terminal
The digital output adopts 2 sets of 10Pin screw-type pluggable terminals with a
spacing of 5.08mm, and the PWM function is integrated in digital output signals.
→
Wiring Definition
Terminal
Name
Type
Function 1
Function 2
OGND
/
External power
/
Summary of Contents for ECI3808