ECI3808 Network Motion Control Card User Manual V1.5
The number of nodes can
be extended
1
Communication Distance
The Longer communication distance is, the lower
communication rate is, maximum 10m is recommended.
→
Wiring Reference
→
Wiring Notes:
⚫
The wiring of RS232 is as above, it needs to cross-wiring for sending and receiving
signals, and it is recommended to use a double-female head cross line when
connecting to a computer.
⚫
Please be sure to connect the public ends of each communication node to prevent
the communication chip from burning out.
⚫
Please use STP, especially in bad environments, and make sure the shielding layer is
fully grounded.
3.3.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use any ETHERNET or RS232 (there is default parameter,
which can be connected directly) to connect to ZDevelop.
(3)
Please use the "ADDRESS" and "SETCOM" commands to set and view the protocol
station number and configured parameters, see "ZBasic Programming Manual" for
details.