Back Plate
2
3.1"(80.0mm)
3.2"(80.3mm)
0.5" (13.0mm)
2.4"(60.0mm)
ProID
3.0"(76.0mm)
4.8"(123.0mm)
LED Indicator
Buzzer
0.5" (11.6mm)
DIP
Switch
MountingHole
ProID101
ProID102
1.4"(36.0mm)
4.3"(109.7mm)
0.5" (12.8mm)
TamperSwitch
Tamper
Page 1: ...QUICK START GUIDE ApplicableModel ProlDSeries Version 1 1 Date March 2023 WaterResistantRFIDAccessControlReader...
Page 2: ...1 Product Overview ProID ProID 0 5 11 6mm 3 4 86 0mm 3 4 86 0mm LED Indicator DIP Switch Mounting Hole LED Indicator Mounting Hole 0 4 11 0mm 1 8 44 5mm 4 4 111 0mm 1 DIP Switch Buzzer Buzzer...
Page 3: ...2 3 1 80 0mm 3 2 80 3mm 0 5 13 0mm 2 4 60 0mm ProID 3 0 76 0mm 4 8 123 0mm LED Indicator Buzzer 0 5 11 6mm DIP Switch Mounting Hole ProID101 ProID102 1 4 36 0mm 4 3 109 7mm 0 5 12 8mm Tamper Switch Ta...
Page 4: ...gand 26 34 Beep Red LED Green LED Tamper RS 485 12V GND RS485A RS485B WD0 WD1 WG26 34 BEEPER RLED GLED TAMPER Wiegand Out 2 Terminal Block 4 4 111 2mm 2 9 73 0mm 0 5 13 0mm 2 4 60 0mm ProID103 3 Tampe...
Page 5: ...fter passing the wires through the wiring hole and connecting them to the device and then attach the device to the back plate from top to bottom Fasten the device to the back plate with a security scr...
Page 6: ...g box mullion mount using two wall mounting screws Pass the cables through the wire hole Then insert the device into back plate Use security screw to fasten the device to the back plate The installati...
Page 7: ...t is parallel a terminal resistance of 120 ohm between 485 and 485 485 Address Switch Setting Switch Setting 1 2 3 4 ON KE 1 2 3 4 ON KE 1 2 3 4 ON KE 1 2 3 4 ON KE 1 2 3 4 485 Address ON KE 1 2 3 4 O...
Page 8: ...1 2 3 4 ON KE 1 2 3 4 Notes 7 1 A maximum of seven readers can be connected to one controller 2 BeforeconnectingRS 485readers opentherearpanelofthereaderandset theRS 485addressofthereaderviaDIPswitch...
Page 9: ...WD1 WD0 GND 12V WG26 34 Note 12V GND RS485A RS485B WD0 WD1 WG26 34 BEEPER RLED GLED TAMPER 12V GND RS485A RS485B Access Control Device 8 ON KE 1 2 3 4 ProlD Series Reader When terminal WG26 34 is conn...
Page 10: ...device is opened and an alarm signal will be sent to the software side 12V GND RS485A RS485B WD0 WD1 WG26 34 BEEPER RLED GLED TAMPER ON KE 1 2 3 4 Controller Recommended 7 to 13V DC Current Draw 350mA...
Page 11: ...s up briefly twice LED bright white light Operation Voltage Current Draw Processor Card Type Read Range Output Format Operating Temperature Operating Humidity Protection Rating Installation Color Cert...
Page 12: ...ZKTeco Industrial Park No 32 Industrial Road TangxiaTown Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2023ZKTECOCO LTD AllRightsReserved...