As shown in the table below, places 1-3 of the DIP switch are used to set the
device number for RS-485 communication, and place 4 is for setting the RS485
termination resistance. If the RS-485 communication wire is longer than 100
meters, it is needed to set the 4th DIP switch of the last reader to
ON
state, that is
parallel a terminal resistance of 120 ohm between 485+ and 485-.