background image

 

Chapter 1 Cable Embedding   1 

Chapter 1 Cable Embedding   

 

Prepare φ25 protective sleeve and cable in advance. 

 

Route cables to be connected through protective sleeves. 

 

Use a tool to open a cable tray on the ground, see Figure 1-1. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1-1 Cable embedding   

 

 

The power wire is wrapped 
and protected using the wire 
sleeve when laid out under 
the ground (the strong 
current should be separated 
from the weak current) 

Control 

room 

Screw pad 

Ground 

Ground 

Cabinet 

Expansion bolt 
4-M12 

Base concrete 

Summary of Contents for PB4060

Page 1: ...Contents I Installation Guide PB4060 Version 1 0 Date July 2018 ...

Page 2: ...Contents Chapter 1 Cable Embedding 1 Chapter 2 Cabinet Installation 2 Chapter 3 Boom Installation 3 Chapter 4 Cabinet Inside 4 Chapter 5 Troubleshooting 6 ...

Page 3: ...h protective sleeves Use a tool to open a cable tray on the ground see Figure 1 1 Figure 1 1 Cable embedding The power wire is wrapped and protected using the wire sleeve when laid out under the ground the strong current should be separated from the weak current Control room Screw pad Ground Ground Cabinet Expansion bolt 4 M12 Base concrete ...

Page 4: ...rk the installation position of the cabinet Drive four expansion bolts into the bolt holes as shown in Figure 2 1 Install screw pads and use a wrench to tighten nuts as shown in Figure 2 2 Figure 2 1 Figure 2 2 Screw pad Ground Ground Base concrete Chassis Expansion bolt Cabinet ...

Page 5: ... Pull the vice boom out from the main boom then fastened by 2 screws as shown in Figure3 1 Installing the boom to the chassis as shown in Figure 3 2 Figure 3 1 Connect the main boom with vice together by 2 screws Figure 3 2 Installing the Boom to the cabinet ...

Page 6: ...ete key Copy press the key and then press any other key of remote controller until the Copy delete indicator light blinking Delete press the key until the Copy delete indicator light blinking then press the Stop of testing key AC power input Connection with 110 220V power according to type of your purchasing ...

Page 7: ...fted up automatically Motor AC power motor Hall sensor Connect to Limited switch port of control board which limited the close open position Shock absorber A gel is used to absorb the pressure of close open boom Spring Using it to keep balance with boom For example the boom changed short opening plastic nuts to make spring loosen a little Otherwise the boom may can t close totally ...

Page 8: ...ent of boom close open A Check whether the shock absorber gel was damaged if yes please replace a new one B Check whether the spring was fatigue deformation if yes please adjust or replace it 3 Boom barrier can t open close totally A After changed shorter boom should have adjusted spring to keep balance B The plug of sensor did not connect correctly 4 The distance of remote controller decrease The...