36
ProBio & ProFAC User Manual
The time period is the
Door Sensor Delay
(value ranges from 1 to 255 seconds).
Door Sensor Type:
It includes
None
,
Normal Open (NO)
and
Normal Close (NC)
.
None
means door
sensor is not in use;
Normal Open
means the door is opened when power is ON;
Normal Close
means
the door is closed when power is ON.
Verification Mode:
Select verification mode to open door, including password / fingerprint / badge /
face, fingerprint only, user ID only, password, badge only and so on.
NOTES:
1. “/” means “or”. “&” means “and”.
2. In a combined verification mode, the corresponding verification information must be registered
first. For example: When User A registers
fingerprint
only, and the
[Verification Mode]
is set as
“Password & Badge”
, User A will not pass verification.
Door Available Time Period
: Set periods to open the door for users.
NO Time Period:
To set time period for Normally Open, so that the door is always unlocked during this
period.
Use as master
: While configuring the master and slave devices, you may set the state of the master as
Out
or
In
.
Out:
A record of verification on the master device is a check-out record.
In
: A record of verification on the master device is a check-in record.
Auxiliary Input Configuration:
To set the
Aux output/lock Open Time
and
Aux Output Type
Setting
for the device with auxiliary connector.
Aux Output Type
Setting
includes
None
,
Trigger
Door Open
,
Trigger Alarm
, and
Trigger Door Open and Alarm
.
Verify Mode by RS485
:
It is the verification mode used by the device when it is the master unit. This
option will be displayed only if RS485 reader function is enabled.
You can enable it by following these steps: In the initial interface, press
>
Comm.
>
Serial Comm
>
RS232/485
>
RS485
>
Master Unit
.
Speaker Alarm:
When the
[Speaker Alarm]
is enabled, the speaker will raise an alarm when the device