BGM1000 Series Barrier Gate (APP Version) User Manual
P a g e
| 21
Copyright©2023 ZKTECO CO., LTD. All rights reserved.
12EXXX
Boom Arm Opening Memory
12E000:
Close
12E001:
Open
When more than two legal access signals are given at the same
time (including the same direction and the opposite direction),
the system will remember all pass requests and complete each
pass in turn.
12E000
13EXXX
Core Component Position
13E000:
Right
13E001:
Left
13E001
14EXXX
Reset
14E000:
-Normal
14E001:
Reset
Select
[14E001]
will restore the default factory setting.
(
Note:
The function does not clear Core Component Position and
Core Component Polarity.)
14E000
15EXXX
Remote Control Pairing
15E000:
Normal
15E100:
Add
15E200:
Clear
Note
: The fourth digit is adjusted by pressing
[+/-]
to add or clear
wireless remotes, and the sixth digit shows the number of
remotes that have been paired with the current device.
15E000
16EXXX
RS485 Address
16E000