BGM1000 Series Barrier Gate (APP Version) User Manual
P a g e
| 19
Copyright©2023 ZKTECO CO., LTD. All rights reserved.
Parameter Settings Description
8.2
Ites
Description
Default
01EXXX
Display Mode
01E000:
Displays current position of the swing arm
01E001:
Controls input signal
01E002:
Test mode (the digital LED displays "---" in the test
mode)
01E102
: Opening position
01E202
: Closing position
01E502
: Opening
01E602
: Closing
01E702
: In the pause
01E003:
Number of boom openings
01E004:
Version Information
01E000
02EXXX
Boom Arm Opening Speed
Set the Boom Arm Opening Speed to open the gate. The larger
the number is set, the faster the speed. The Boom Arm Opening
Speed value can be set between 10 to 32 and the default value is
24.
02E024
03EXXX
Boom Arm Opening Brake Stroke
The larger the number, the longer the deceleration time and the
more stable the boom arm operation. The Boom Arm Opening
Brake Stroke can be set between 0 to 100 and the default value is
30.
03E030
04EXXX
Boom Arm Opening Brake Speed
The smaller the number, the more pronounced the deceleration
effect. The Boom Arm Opening Brake Speed can be set between 5
to 100 and the default value is 10.
04E010