background image

Magnetic Lock User Manual

Wiring: 

The positive phase and negative phase are connected to the power box. Use the model that has signal output. 

             Signals are connected as required by users:
1.Connected to COM and NO if normal open signals are necessary; 
2.Connected to COM and NC if normal close signals are necessary;
3.The indicator lamp turns red if the lock is separated from the adsorption plate or if contact is not thorough. The lamp 
   will turn green if the lock and the adsorption plate contact with each other correctly. 
4.In case of abnormal indicator lamp when the lock is working, it may be caused by improper contact between the lock 
   and the adsorption plate. Adjust the position of the lock and the adsorption plate to ensure thorough contact.

Precautions:

 

1. Cables shall be larger than 0.75mm2 in case of power supply with a large power capacity (the output of power supply controlled within 12VDC

±

15% strictly).

                            2. The screw connecting locks and 

Armature plate

 shall be tightened. Check the fixing of the lock and the board after three months.

                             3. Install carefully to avoid damage to 

Armature plate

 and the galvanized coating of locks, and otherwise, the normal use, suction force and service life will 

                                 be damaged.
                            4. The complete contact between the 

Armature plate

 and the lock as well as the size of contact surface will decide the suction force directly. 

                             5. A rubber ring is required between the 

Armature plate

 and the lock so as to maintain a proper flexibility of the suck board, and tensive screws of the 

                                

Armature plate

 shall not be fixed too tightly in order to maintain the appropriate flexibility of rubber ring. 

                            6. 

Armature plate

 cannot be welded on the door directly, and otherwise, the normal use of magnetic locks will be damaged.

                            7. Wipe off rust-preventive oils on the locks with cotton cloth while alkaline or irritant detergents not allowed. 

Armature plate

NC

GND

NO

PUSH

12V

GND

GND

12V

-

+

UPS

Control

NC NO

COM

-

+

A L - 1 8 0

A L - 1 8 0 D

A L - 2 8 0 ( L E D )

A L - 2 8 0 D ( L E D )

3 3 2 X 2 1 X 4 0

1 6 6 X 2 1 X 4 0

2 5 3 X 2 5 X 4 8

5 0 6 X 2 5 X 4 8

380

760

500/250

1000/500

500/250

700/350

1000/500

2 5 3 X 2 8 X 5 5

5 0 6 X 2 8 X 5 5

2 8 0 X 3 8.5 X 7 0

A L - 3 5 0 ( L E D )

A L - 3 5 0 D ( L E D )

A L - 5 0 0 ( L E D )

2 4 V  1 0 %

A L - 1 8 0 M

1 9 8 X 2 1 X 3 5

380

1 2 V  1 0 %

Model

Dimensions (mm)

Vol tage  

(DC )

Curr ent  

(mA)

Indicator Lamp & Signal 
Output (NC/NO)

AL-350(LED)

       

 10.During installation of this product, offset (toward right, left, upside and downside) of center position of both the adsorption plate 

        and the lock shall not exceed 3mm.

Door frame not 
less than 5mm.

Y

X

O

Series

Thickness

A1

Thickness

A2

Direction

Left

Right

Up

Down

X(mm)

Y(mm)

Door Frame

Door Frame

AP-180

AP-280

AP-350

AP-500

>38

>48

>43

>53

>46

>56

>58

>68

3

3

3

3

0

0

0

0

(mm)

(mm)

1 2 V  1 0 %

Wood
Door

Pull out

Electric Strike Series

Magnetic Lock Series

El ect ric Bolt  Lock  ser ies

Brackets and Accessories

Me cha ni cal Lo ck Se riess

El ec tron ic Lo ck Se ries

Electric Strike Series

Magnetic Lock Series

El ect ric Bolt  Lock  ser ies

Brackets and Accessories

Me cha ni cal Lo ck Se riess

El ec tron ic Lo ck Se ries

        

Wel co me to us e Adv an ced  Lo ck prod uc ts. In order  to protect  yo ur righ ts an d inter ests,  read  thi s User  Man ua l caref ul ly be fore  us e. Please  

co ntact  the de al er or the man ufact urer  in case  of qu ery .

ELECTRIC  LOCKS

Applicable Range: 

This lock is applicable for use together with building interphone and access control system. This lock is applied extensively in 

                                security door, emergency door and fire door. 

Product Advantage: 

The magnetic lock adopts professional magnetic materials and special processing workmanship. No residual magnetism is 

                                produced even after long time operation. Long-time use will not cause magnetization of adsorption plate and result in reduction 
                                of adsorptive force. This lock has longer service life and is free of mechanical failure, abrasion and noise. 
                                

Auxiliary bracket can be used for installation of frameless glass door. 

o

Door Opening:  

90  

Electrical Property:

 Users can select suitable products with different models and functions based on the following table. Customization is available 

                                  according to users' requirements.

Not provided

Not provided

Not provided

Provided

Provided

Provided

Provided

Provided

Access control 
power source

Access 
controller

Pull out

1400/700

560

X 3 8.5 X 7 0

A L - 5 0 0

D

( L E D )

Provided

(2000)量认(国)字(H0992)号

太平洋承保

Summary of Contents for AL-100

Page 1: ...eration o Door Opening 90 and available for load of 250kg Electrical Property Users can select appropriate products with different models and functions based on the following table Customization is available according to users requirements 12V 15 Model Voltage DC Current mA AL 130NO AL 130NC 240 120 Mechanical Lock 3 3 5mm 1mm AL 130 Series Electric Strike Installation Drawing Electric strikes Ele...

Page 2: ... Opening 90 and available for load of 400kg Electrical Property Users can select appropri ate products with different models and functions based on the following table Customization is available acco rding to users requirements 12V 15 Model Voltage DC Current mA Unlock Method AL 131NO 240 3 3 5mm 1mm Door Frame Electric strikes Electric strikes 150 135 100 32 48 5 28 3 44 5 AL 131NO AL 131NC NC GN...

Page 3: ...kg Electrical Property Users can select appropri ate products with different models and functions based on the following table Customization is available acco rding to users requirements Wiring 1 One diode is an accessory provided in the accessory bag The diode is used to prevent bounce back current and voltage produced during locking or unlocking from affecting the access control mainframe Users ...

Page 4: ...r with anode mechanical lock or ball lock in office buildings wooden doors stainless steel doors fire doors and entrance gate of residence community Product Advantage Recessed type installation pleasant looking appearance wide lock mouth and more extensive application The electromagnetic part adopts high quality magnetic materials and special processi ng workm anship to ensure normal use and no re...

Page 5: ...blue wire refer to COM common wire NC normal close and NO normal open respectively The purple wire and orange wire output NC normal close lock signals Limited current of lock status signal is 300mA when the input voltage is 12VDC Overload is forbidden Locking and unlocking status can be monitored after it is connected to the central control room Remark can be customized Se e Diagram 1 AL 100 Door ...

Page 6: ... Fix the lock and the decoration plate on the doorframe based on the holes Step 5 Decide the center line according to the door electric bolt lock and the bolt Then stick the perforated paper to the door Step 6 Use special drilling tool to drill holes on relevant type of magnetic buckling plate according to corresponding electric bolt lock Step 7 Fix the magnetic buckling plate on the door with scr...

Page 7: ...6X25X48 380 760 500 250 1000 500 500 250 700 350 1000 500 253X28X55 506X28X55 280X38 5X70 AL 350 LED AL 350D LED AL 500 LED 24V 10 AL 180M 198X21X35 380 12V 10 Model Dimensions mm Voltage DC Curr ent mA Indicator Lamp Signal Output NC NO AL 350 LED 10 During installation of this product offset toward right left upside and downside of center position of both the adsorption plate and the lock shall ...

Page 8: ... A1 166 253 253 280 D Sucking Disk H L Sucking Disk T sucking Disk Series Model Dimension Identification Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser ies Brackets and Accessories Mechanical Lock Seriess Electronic Lock Series Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser ies Brackets and Accessories Mechanical Lock Seriess Electronic Lock Series Push in...

Page 9: ... rotate direction Diagram Diagram Diagram Outside Inside The sign refer to rotate direction Outside Inside Outside Inside Inside Outside Door Z bracket L bracket Outside Inside Door frame L bracket Lock body Armature plate rubber ring Z bracket Diagram of Magnetic Lock Auxiliary Bracket Installation Procedures Inward opening Door AL 180PL AL 280PL AL 350PL AL 500PL AL 500DPL AL 180PZ AL 280PZ AL 3...

Page 10: ...ame Install the tamper screw Door frame Door frame Glass door Glass door Glass door Small metal plate for height adjustment Screw Outside Inside Step 7 Use screws to fix the sub plate and the U bracket Their positions shall be consistent Make sure the rubber ring is installed during installation AL 180PU Step 8 Installation effect Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser...

Page 11: ...wn in Fig 6 Glass door The U bracket clamps upwards the glass frame according to thickness use spacer of the glass door After correction of the position fix it on the glass frame Note In case both the upside and downside parts are frameless glass the distance between glass door and doorframe shall not be less than 7mm In case only one part is frameless glass the distance between glass door and doo...

Reviews: