background image

Page 34 of 36 

802265US v1.27 06.21 BCS, BCS100-75 Install Instructions

Limited Warranty- Zip Products

What Does This Warranty Cover?

Culligan International Company, d/b/a Zip Water, (hereinafter “Zip”), warrants to the original purchaser (the “Zip 

Customer”) of the Zip product (the “Zip Product”), so long as the Zip Customer purchased the Zip Product from an 

authorized Zip dealer (“Authorized Zip Dealer”), that this Zip Product, including any of its original accessories, is free of 

defects in material and workmanship, subject to the terms and conditions set forth herein. This Limited Warranty covers 

parts and labor, except as set forth in this Limited Warranty

Where Is This Limited Warranty Valid?

This Limited Warranty is only applicable if the Zip Product was installed in the United States of America (“USA”).

What Is Required to Request Warranty Service?

All three of the following are required before warranty service will be performed:  (1) Verification of the purchase date; 

(2) Verification that the Zip Product was purchased from an Authorized Zip Dealer; and (3) Verification that the Zip 

Product at issue was installed by an authorized Zip service technician or an approved Zip service provider.

When Does the Limited Warranty Expire?
One (1) Year Limited Warranty

 - Any warranty claims for Zip Products must be received by Zip within 15 months 

from the date of purchase or within 12 months from date of installation.  This warranty guarantees that if any part 

should fail within 15 months from date of purchase or within 12 months from the date of installation, except as detailed 

below, Zip or its authorized service provider will repair or replace the Zip Product.  Determination to repair or replace 

will be in Zip’s sole discretion. Repair or replacement services will be at no cost to the Zip Customer, provided that:
a)  the Zip Product is installed and used strictly in accordance with the instructions supplied; and
b)  all service under the One (1) Year Limited Warranty is carried out only by an authorized Zip service technician or 

an approved Zip service provider.
This warranty includes both parts and labor.

Extended Two (2) Year Limited Warranty

 – In addition to the One (1) year Limited Warranty described above, 

the Zip Customer can opt to extend the Zip Product warranty by one (1) year, making the total Limited Warranty period 

two (2) years. In order to extend the warranty to two (2) years, the Zip Customer must register their product with Zip. 

This extended two (2) year Limited Warranty is subject to the same conditions as provided above in clauses a) and b).

How To Register?

Zip Products must be registered online at https://www.us.zipwater.com 

What If Repair Is Impossible?

If Zip determines that the warranted repair of any Zip Product is impossible, the Zip Product shall, at Zip’s discretion, 

either be replaced or refunded. 

What Is Not Covered by This Limited Warranty?
This Limited Warranty does not cover:

•  Damage or defects caused by, or resulting from, repairs, service, conversion or alterations to the Zip Product 

or any of its parts and accessories which have been performed by service centers or repairmen not authorized by 

Zip; damage or defects caused by negligence, improper installation (when not installed by an authorized Zip service 

provider), accident, abuse, misuse, power interruptions, power surges, unsuitable water conditions, floods, natural 

disasters, or force majeure; or improper maintenance of the Zip Product or its parts or accessories.
•  Ordinary wear and tear.

Warranty

Summary of Contents for HydroTap BCS Series

Page 1: ...27 06 21 BCS BCS100 75 Install Instructions Page 1 of 36 BCS100 75 and BCS Series Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document Eng...

Page 2: ...before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Installation instruction book supplied with the faucet For all operational features o...

Page 3: ...s cylinder Section 3 CO2 Cylinder 3 1 Secure the cylinder cradle 14 3 2 Connect the regulator 14 3 3 Connect the gas hose 14 3 4 Test for gas leaks 14 STEP 4 Install the Command Center Section 4 Comma...

Page 4: ...unter cabinet supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the Command Center has been installed correctly 2 Check all plu...

Page 5: ...water and an immersion heating element to boil the water and all utilise a CO2 gas cylinder to carbonate the chilled water Depending on the model these units will dispense boiling water factory set t...

Page 6: ...ction Venting Sometimes steam and or condensed droplets may discharge through a vent outlet at the faucet If the faucet is not installed using the Font pedestal ensure the faucet body is located so th...

Page 7: ...ocated near or cleaned with water jets 7 Zip HydroTaps are not to be exposed to the elements of nature 8 Due to the process of continuous improvement Zip reserves the right to change details mentioned...

Page 8: ...ent 1x Outlet vent 9x Screws 1x Installation Instructions this book and 1x User Guide 1x CO2 gas cylinder regulator assy Major components and accessories Accessories Description Softener and head asse...

Page 9: ...been certified by IAPMO R T against NSF ANSI Standard 372 for low lead requirement NSF ANSI Standard 42 NSF ANSI Standard 53 CSA B483 1 ASSE 1023 and ASSE 1087 This will deliver the required bacterios...

Page 10: ...ection point and the stop cock will not be obstructed when the Command Centers are installed For the Celsius All In One an external hot and cold water supply will be required For other faucets the sys...

Page 11: ...saw and a 12mm Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps...

Page 12: ...ing temperatures then the inlet vent and door outlet vent See item D below will need to be fitted Alternatively a fan kit may be installed using the AUX din plug of the right hand side of the applianc...

Page 13: ...let and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure with 5 screws 4 Fi...

Page 14: ...water before re applying Do not force the seal to fit Turn the regulator OFF by rotating the regulator knob all the way out in an anti clockwise direction NOTE Two plastic seals are supplied with a n...

Page 15: ...for leaks 4 If any bubbles appear the joint will need to be resealed CO2 Regulator Leak Test Pressure regulating knob ON OFF knob Green zone Relief valve NOTE Be careful not to lose the small sealing...

Page 16: ...etermine which bypass position you need for your product Section 4 Command Center Installation A Rotate 90 only 1 2 3 4 NOTE Before installation determine whether a water softener or an external filte...

Page 17: ...le 2 Remove any swarf or unwanted material 3 Push the tube into the John Guest fitting making sure all connections to the John Guest fittings are pushed in past the O ring to full depth at least 15mm...

Page 18: ...e the the hoses need to hoses need to have a constant have a constant downward downward gradient to the gradient to the HydroTap to HydroTap to allow all water allow all water to drain back to drain b...

Page 19: ...UT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT SPARKLING OUTLET CO2 IN WHITE External HOT and COLD isolation valves Not Supplied Note Note the the hoses need to hoses need to have a constant have a...

Page 20: ...commissioning the system may be customised by selecting further options in Section G Settings within the User Guide BC Sparkling 10 30 Wed 04 Jul 2018 BC Sparkling 10 30 Wed 04 Jul 2018 A new filter c...

Page 21: ...lected BC Sparkling 10 30 Wed 04 Jul 2018 BC Sparkling 10 30 Wed 04 Jul 2018 NOTE For any subsequent filter changes or any operational procedures please refer to the HydroTap user guide located inside...

Page 22: ...liters 2 6 gallons of chilled water from the chilled outlet of the HydroTap equivalent to 4 complete tanks full of water 3 If water bubbles or foams repeat steps 1 and 2 above 4 Let filled tanks stand...

Page 23: ...y backflow of gas and or water out of the internal carbonator In addition to the HydroTap s integral Backflow prevention Some authorities require additional Backflow Prevention to be installed to comp...

Page 24: ...iver fault No chilled water Call Zip Service Hot sensor degraded Internal fault Call Zip Service Condenser overtemp Blocked air filter Remove blockage Clean filter check user guide A DC Pump is faulty...

Page 25: ...than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements...

Page 26: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Page 27: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Page 28: ...limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Red...

Page 29: ...ss than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requiremen...

Page 30: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Req...

Page 31: ...o the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requi...

Page 32: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requ...

Page 33: ...al to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction R...

Page 34: ...the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is installed...

Page 35: ...icer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is committed to r...

Page 36: ...and against NSF ANSI Standard 42 and NSF ANSI Standard 53 This will deliver the required bacte riostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to...

Reviews: