HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1.05
Page 6 of 24
Read These Warnings
continued
Altitude
The Zip HydroTap is equipped with a self-calibrating program which caters for
altitude adjustment.
Filter Control
The Zip HydroTap filter control is preset to 6000 litres to provide trouble-free flow
and operation in most installations. Local water quality conditions may require an
alteration to this capacity. In areas where the water has a high concentration of
sediment, the preset litre capacity may be shortened to avoid poor flow, taste or
odour situations. In areas where the water quality is above average, lengthening
the preset capacity may be desirable, but not essential. If any of these changes is
needed, follow the instructions on page 16 or contact your Zip Service Provider.
Frost Protection
If this appliance is located where the ambient air temperature could fall below
5ºC when the heater is not in use, do not turn off the appliance electrically. This
safeguard does not offer the same protection to the connecting pipework and
fittings.
Environment Considerations
This unit is intended for indoor use only and should never be installed outdoors or
exposed to the elements of nature. This unit must not be positioned in an area that
may be cleaned by a water jet and must not be cleaned by a water jet.
Warning:
Zip HydroTaps are designed to operate within 1ºC to 2ºC of set point for boiling
water and at 5ºC to 15ºC for chilled drinking water. All boiling water units are
self calibrating to 98ºC, which is the recommended setting. Adjustments to the
recommended setting of 98ºC setting are not advised, however, under certain
circumstances adjustments may be made between 68º - 100ºC . The 100ºC setting
is not recommended as units may discharge or boil over more frequently.
For details see step G on page 12.
Caution
must be observed when changing any settings within the Service
Menu as any changes may affect the normal operation of the unit.
Note:
Always ensure the silicone tubes are shortened so that any excess is removed
and their route is the most direct line between the tap assembly and the
HydroTap unit.
Do not allow the tubes to sag or droop so water is trapped within the hoses.
Always maintain a constant fall.
Positioning of the tap assembly must be within the following parameters:
The height between the base of the Hydrotap unit and the base of the Tap
assembly cannot be greater than 900mm.