background image

HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1.05 

                   Page 18 of 24

Press either Mode 

<

or Mode  < button until “Litres Filtered” is displayed. 

Press 

<

 Adjust once and “Reset Counter” will be displayed, press 

<

 Adjust 

button once and “Are You Sure” will be displayed.

Press 

<

 Adjust once and “Litres Filtered” will be reset to 0.

Activating Sleep Mode 

This mode allows the HydroTap to go into Energy Saving mode. In this mode 
the unit will go to “sleep” after a predetermined period of inactivity.  
Press either Mode 

>

 or Mode 

>

 button until “Sleep Mode” is displayed.  

Press 

>

 Adjust once to select.

Option 1:

 Sleep to 65ºC after 2 hours of NO USE 

Press 

>

 Adjust once to select.

Option 2:

 Auto OFF after 2 hours of NO USE. 

When the period of inactivity passes, the display will show “Sleep Mode”. 
During the “Sleep Mode” the Red LED on top of the tap lever will flash slowly. 

Sleep to OFF means the Boiling and Chilled circuits will be switched OFF.

De-Activating Sleep Mode:

Momentarily operate the Hot lever on the HydroTap and then allow sufficient 
time for the water to reach the set temperature.

Activating On / Off Mode 

Press the Mode

<

 or Mode  <  button until “Monday On” is displayed. To set 

the time for the unit to turn on press 

<

 Adjust button until required time is 

reached. 

To set the time for the unit to turn Off press Mode

<

 button once and “Monday 

Off” will be displayed. Now press

<

 Adjust until required time is reached.

If each individual day is to have an “On / Off” time, these steps need to be 
repeated for each day and for each On / Off time.

Note:

The HydroTap may be temporarily activated during the On / Off Mode. By 
operating the levers, the unit will go into normal operation and then remain in 
an “ON” cycle, until the next “OFF” cycle.

Operating the Mixer tap will not De-Activate the sleep mode or the energy 
saver On/Off timer mode.

Setting the Energy Saver Timer 

(continued)

Auxiliary Fan Attachment

The HydroTap is equipped with an auxiliary fan connection point  on the rear 
panel close to the cold water inlet / flex and plug area. The fan kit is available 
as a spare part. The fan operates in parallel with the Condenser fan helping 
to remove heat from the cupboard space. This fan should be purchased and 
connected to the HydroTap if the airfow characteristics of the cupboard space 
are inadequate for the effective removal of hot air, thereby adversely affecting 
the operation of the HydroTap.

The fan can be installed so that it extracts air from, or forces air into the 
cupboard space, whichever is the most effective for your installation.

Application of the fan is of paramount importance in situations where the 
cupboard space reaches temperatures greater than 35ºC. 

The exhaust fan kit must be fitted, when supplied with the appliance.

Note: 200/175 model is supplied with the auxiliary fan kit.

Auxiliary fan

connection

Cold water
connection

Electrical

connections

Summary of Contents for HydroTap 4-in-1

Page 1: ...ydroTap 4 in 1 and Zip HydroTap 3 in 1 Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction cover...

Page 2: ...HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05...

Page 3: ...the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all...

Page 4: ...d BC assemblies which have been factory modified to accept a secondary mixer tap The mixer tap is connected so that it draws water directly from the cold water mains as well as from the boiling water...

Page 5: ...responsibility to supply if necessary and install all valves as required by local regulations and relevant standards The plumbing installation must be done in accordance with local Water Authority re...

Page 6: ...unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature This unit must not be positioned in an area that may be cleaned by a water jet and mus...

Page 7: ...ation site Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the unde...

Page 8: ...nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more...

Page 9: ...he undersink unit SPECIAL NOTE The HydroTap undersink units are heavy take note of the weights listed in the table on page 7 If you think you cannot lift the unit safely get help and avoid possible in...

Page 10: ...ny excess or allow kinking of the tubes When connecting slide the tube over the pipe at least 25mm There are black plastic clamps provided on the boiling and chilled hoses to choke the flow if require...

Page 11: ...responds to the direction indicated by the arrow on the filter head and by the instructions listed on the rear panel of the under sink unit Check the lower left hand John Guest fitting is the Inlet fr...

Page 12: ...and exit model description selection setting 4 The model selection is now complete The Start Filt Flush will be displayed Fig d Start Filt Flush Press Adjust Fig d Scroll Exit BC160 125 Press ADJUST o...

Page 13: ...nce to return to the service default screen To change the service default screen back to Normal Operation press the adjust buttons together until the screen changes back Warning Caution must be observ...

Page 14: ...n trap spigot available If a spigot is not available use the snap on spigot and worm drive clamps supplied in the kit Instructions and diagrams are supplied in the kit 8 Ensure the positioning of the...

Page 15: ...to be manually returned to the Off position Chilled Water Lever Depressing the Blue lever allows dispensing of Chilled water Pulling up the Blue lever allows the tap to operate in a no touch mode Wate...

Page 16: ...ox 10 seconds it will default to the selected mode The Zip HydroTap notifies when filter replacement is due The default setting is 6000 litres but this can be set in increments of 1000 litres from 100...

Page 17: ...touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs with the slots on the under side of the filter head 10 Slide cartridge...

Page 18: ...once and Monday Off will be displayed Now press Adjust until required time is reached If each individual day is to have an On Off time these steps need to be repeated for each day and for each On Off...

Page 19: ...enu and selecting de activate when Hot isolation Mode is displayed on the screen 7 The LCD will show Normal Operation Set The Boiling Chilled Water Dispensing Times The ability to change the maximum d...

Page 20: ...Boiling water to any one sink or may be fitted with a Font kit when a sink is not available The Font must be connected to a suitable drain NOTE The Venturi connection for the 4 in 1 Mixer tap is locat...

Page 21: ...lves 1 2 Page 22 Faulty restrictaflow valve Clean and reset restrictaflow valve item 3 Page 22 Water supply not connected Check plumbing connection turn water ON No hot water from mixer Hot tank empty...

Page 22: ...ion and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Page 22 of 24 Trouble Shooting Continued 1 2 3 Item Description Part No 1 Chec Valve 15mm SP88508 2 Check Valve 8mm SP8850...

Page 23: ...Page 23 of 24 HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Notes...

Page 24: ...s incurred by a Zip Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty...