Installation Procedure
continued
Step F - Connecting the water supply
To prevent sediment from entering the Zip HydroTap at connection, flush water
through the supply line thoroughly before connection to the Zip HydroTap.
Open the access door and check that the filter is in place and secure. Connect
the water supply to the undersink unit using the attached flexible hose.
Turn on water and check for leaks. If no leaks are evident turn the power on.
Step G- Testing and commissioning
Use these buttons to
scroll through the menu
Use these buttons to
activate and de-activate
the program selected
Model Selection
1. When first turned on, the screen will display general product information
for approximately 2 seconds (
Fig.a)
.
2. The screen will then display ‘To Select Model Press ADJUST ->’. Press the
ADJUST
>
or
>
button once to check the model number (
Fig.b)
.
3. The screen will now display ‘<-Scroll Exit->’ and the model
description (
Fig.c)
. The factory default model description on the screen
should match the product model description on the front cover of this
instruction manual. If the correct model description is displayed, select
‘Exit’ by pressing ADJUST
>
or
>
to confirm selection and exit model
description selection setting.
If the model description displayed is incorrect, select the ‘Scroll’
option by pressing MENU
>
or
>
button to scroll through the model
discription until the correct model description is displayed then select
‘Exit’ by pressing ADJUST
>
or
>
to confirm selection and exit model
description selection setting.
4. The model selection is now complete. The ‘Start Filt Flush’ will be
displayed (
Fig.d)
.
Start Filt Flush
>Press Adjust
>
Fig.d
<- Scroll Exit->
BC160/125+
Press ADJUST
>
or
>
to exit
ADJUST
Press MENU
>
or
>
to scroll through the model numbers.
Zip Industries
HTAP BC 1.30E11S
Fig.a
To Select Model
Press ADJUST ->
Fig.b
Fig.c
Filter Flush Mode
Have a bucket or similar container (not supplied) at the ready to hold a
quantity of water that is ejected while the Filter Flush Mode is in operation.
Open the filter access door on the front of the HydroTap and the filter cartridge
will be exposed. Located to the rear RHS of the cartridge is a fixed flush line,
approx 600mm long and the flush line stop cock. Place the free end of the
flush line into the bucket or container (not supplied).
Turn “ON” water supply and open the flush line stop cock. The display will
show Filter Flush Mode. To activate press adjust < Run at least 7.5 Ltrs of
water through to activate the filter membrane.
Press the adjust
<
button again to stop the Filter Flush Mode.
Turn OFF the
Filter Flush stop cock and re-locate the tube and stop cock in the filter
compartment.
Turning OFF the Filter Flush Mode puts the HydroTap into
calibration mode. Press adjust
<
to start calibration. The element will now
cycle ON and heat the water to 90ºC maintaining it at that temperature for a
short stabilization period.
Once stabilized, the element will cycle ON, bring the water to boiling point and
hold it there for a short period.
The unit now carries out a self calibration function to ensure correct
temperatures are maintained. During this period the Red LED on the Tap Head
assembly flashes slowly until the calibration function is complete.