807066 v1.00 03.21 HBP AB Install Instructions
TECHNICAL SPECIFICATION
Tank
size
(litres)
Heat up
time
(Inlet
15°C)
Heat up
time
(Inlet
10°C)
Rated voltage and power
Dimensions
W x D x H
(mm)*
Filled
weight
(kg)
3.0
16mins
17mins
220-240V, 50Hz, 1500W
(AU/NZ)
220-240V, 50Hz, 1400W
(non-AU/NZ)
220V, 60Hz, 1250W
300 x 183 x 439
12
5.0
16mins
17mins
220-240V, 50Hz, 2200W
220V, 60Hz, 2000W
329 x 201 x 473
15
7.5
23mins
23mins
329 x 201 x 586
20
15.0
40mins
43mins
220-240V, 50Hz, 2400W
401 x 301 x 606
33
25.0
47mins
50mins
401 x 301 x 786
47
40.0
60mins
64mins
220V, 50Hz, 6000W
415V, 50Hz, 6000W
526 x 286 x 847
70
* add 28mm to Depth for Fascia (Hydroboil Plus)
add 98mm to Depth for Tap and Fascia (Autoboil)
Before installation, ensure that:
• All technical specifications and instructions have been reviewed and understood.
• The mounting wall can support the product weight when full of water. See Technical
specifications.
• Sufficient space is provided to install the appliance and other components in accordance
with these installation instructions. Check cable and plumbing against inlet /outlet
positions before proceeding.
• An easily accessible socket and double pole isolation switch (correctly rated for the
appliance) is required. For models rated below 3kW: 220-240V AC 50-60Hz; for models
rated above 3kW: 380-415V AC mains power.
• The appliance must be connected to a potable water supply with working pressure of: AU/
NZ 150 - 700 kPa (1.5 - 7.0 bar); UK 70 - 500 kPa (0.7 - 5.0 bar).
• The appliance must be connected with an isolating valve within reach of the hose and
positioned so that the valve will not be obstructed.
• A 350 kPa (3.5 bar) pressure limiting valve (not supplied) must be fitted if the incoming
mains water pressure is likely to exceed 500 kPa (5.0 bar)
• The appliance must be placed upright with its base in a horizontal position.
IMPORTANT! Do not proceed with the installation if these
requirements are not met.
!