Zip Command-Centre Installation Instructions Manual Download Page 7

804052UK - Residential chilled and sparkling installation instructions - Sept 2016 - v3.02 

Page 7 of 20

CO

2

 - Disposable cylinder

Compressed carbon dioxide, food grade

Cylinder specifications

• UN No. 1013 

• Class 2.2

• Code ZT400 

• Volume 2.2 litres

• Contents 1kg 

• Tare 1.745kg

• Test pressure 12 MPa (120 bar) 

• Boiling point -78.5°C

• Non flammable gas 

• Non toxic gas

• Std: EN12205 

• Temp range -20°C to +65°C

Important safety instructions

WARNINGS

• 

 The Zip HydroTap

®

G4 Command-Centre

TM

 must be earthed. The 

resistance of the earth connection from each exposed metal part must be 

less than 1

.

• 

All installation and service work must be completed by trained and suitably 

qualified tradespeople. Faulty operation due to unqualified persons working 

on this product, or any other Zip product may void warranty coverage.

• 

As the installer, it is your responsibility to supply (if necessary) and install all 

valves as required by local regulations and relevant standards.

• 

This Zip HydroTap

®

G4 Command-Centre

TM

  is rated for 230V 50Hz AC 

operation.

• 

Do not remove the cover of the appliance under any circumstances without 

first isolating the appliance from the power supply.

• 

 The Zip HydroTap

®

G4 Command-Centre

TM 

must never be located near, or 

cleaned with water jets.

• 

Do not expose the Zip HydroTap

® 

G4 to the elements of nature.

• 

Due to the process of continuous improvement, Zip reserves the right to 

change details mentioned in this manual, without notice. 

 

CO

2

 Cylinder warnings

• 

Pressurised container.

• 

Protect from sunlight.

• 

Contains gas under pressure, may explode if heated.

• 

Do not expose to temperatures exceeding 50˚C.

• 

Do not pierce or burn, even after use. 

• 

Do not refill – non rechargeable.

• 

Ensure cylinder is empty before disposal.

• 

Do not expose to naked flame or any incandescent material.

• 

Keep out of reach of children.

• 

High concentration of gas may cause asphyxiation.

• 

Use only in ventilated areas.

• 

Store in an area no less than 38 cubic meters.

• 

Use only in an upright position.

• 

This bottle must be used with the approved pressure regulator.

• 

Avoid shock.

• 

Use according to MSDS. (Material safety data sheet).

Visit www.zipwater.com/uk to ensure you have the latest copy.

Summary of Contents for Command-Centre

Page 1: ...02 Page 1 of 20 Zip HydroTap G4 Installation instructions Chilled sparkling model Command CentreTM Filtered chilled and sparkling drinking water for residential kitchens Affix model number label here...

Page 2: ...taps to suit the customer s needs Classic HydroTap G4 range Arc Cube HydroTap G4 range Elite HydroTap G4 range These standalone taps are directly compatible with the G4 Command CentreTM Celsius HydroT...

Page 3: ...ead Step 2 Check for adequate ventilation Section 1 Ventilation 1 1 Ventilation on all models 11 Step 3 Fit the CO2 gas cylinder Section 2 CO2 cylinder and regulator 2 1 2 4 Connect secure and test th...

Page 4: ...er cupboard floor has sufficient strength to support the Command CentreTM when full of water see page 9 for weights Before commissioning Check the Command CentreTM has been installed correctly Check a...

Page 5: ...r residential applications The Zip HydroTap G4 Command CentreTM utilises a conventional refrigerant compressor to chill the water and uses a CO2 gas cylinder to carbonate the chilled water The Command...

Page 6: ...n To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Lifting Take...

Page 7: ...nd CentreTM is rated for 230V 50Hz AC operation Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply The Zip HydroTap G4 Command...

Page 8: ...o that the connection point and the stop cock will not be obstructed when all the undersink units are installed For Zip HydroTap 160 125 160 175 models a 220 240Vac 10A GPO will be required For Zip Hy...

Page 9: ...sparkling models 1x13A 0 35 280 x 405 x 333 30kg Min Max water supply pressure HydroTaps and Mains All in One taps 0 25 MPa 2 5 bar 0 7 MPa 7 bar Chilled and sparkling HydroTap G4 range Chilled spark...

Page 10: ...40V AC 13A socket will be required The Command CentreTM must be installed in accordance with IEE regulations See Technical specification page 9 for power ratings Note Check all cable and hose lengths...

Page 11: ...the cupboard position A2 Where possible air inlet vent and the air outlet vent should be positioned at opposite ends of the same cupboard space 1 1 Ventilation for all models The clearance envelope di...

Page 12: ...upright position 2 2 Connect the regulator Remove the gas cylinder from the strap Make sure the regulator knob is turned fully clockwise to the end stop before fitting Screw the regulator clockwise o...

Page 13: ...eak test to check for gas leaks between regulator and cylinder and between regulator and braided hose Stage 1 1 Turn the gas off 2 Using soapy water applied with a sponge or with a brush cover all of...

Page 14: ...mand CentreTM The blue chilled and white sparkling pipes must be insulated with the sleeving provided CHILLED OUT Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the...

Page 15: ...lope Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the Command CentreTM according to the hose and cable lengths supplied 3 3 Chilled sparkling and mixed hot cold C...

Page 16: ...oning the system may be customised by selecting further options in section G Settings of the user manual Section 4 Commissioning Commissioning Press the MENU button for main menu Press the Install but...

Page 17: ...ter Flush Menu Stop cock operation Have a bucket or similar container not supplied at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation Open the fi...

Page 18: ...ocked Blocked air filter Remove blockage clean filter check user guide Water leak Isolate Mains Water leak Turn off mains water supply call for service Compressor Over Run Compressor too hot Check ven...

Page 19: ...n of the appliance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the app...

Page 20: ...rks of Zip Heaters Aust Pty Ltd Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US510385...

Reviews: