STORAGE  WARNING 
WARNING!

 

The cylinder ( containing 1kg of CO

2

 ) should be installed in a well ventilated area 

of area no less than 38m

3

.

If more than 1 gas cylinder containing 1kg of CO

2

 is present within the same location, the recommended 

ventilation area should be in proportion to the number of gas cylinders stored in that location.

A ventilated area in a non-enclosed area which could include the kitchen, living room etc.

See gas cylinder and MSDS sheet for complete list of warnings.

2.1

 

Secure the cylinder

Secure the gas cylinder supplied to a suitable wall, within 1 metre of the Command-Centre

TM

, in an upright 

position. This is undertaken by screwing the metal bar holding the hook-and-loop strap to a cupboard wall, 

200mm above the floor or base of the cupboard. Make sure the gas cylinder can stand in place before 

securing to the wall. Due to regulatory requirements the gas cylinder must be stored securely and in an 

upright position. 

2.2 Connect the regulator

Remove the gas cylinder from the strap. Make sure the regulator 

knob is turned fully clockwise to the end-stop before fitting. 

Screw the regulator (clockwise) onto the cylinder. Be aware that 

some CO

2

 may be discharged from the connection between the 

cylinder and the regulator when assembled together. Any CO

2

 

released will be cold. Screw on the regulator to stop this leakage.  

Note

 The leaking CO

2

 will be cold.

2.3 Connect the gas hose 

Connect the threaded end of the braided gas hose to the 

regulator. Then connect the push fit fitting to the top of the 

Command-Centre

TM

 via  connection marked ‘CO

2

 IN’. 

To turn the gas on, rotate the regulator knob anti - clockwise to 

the end stop. 

2.4 Test for gas leaks

Using soapy water perform a leak test. Apply the soapy water 

to the gas connections using a sponge or brush. If any bubbles 

appear and grow, there is a gas leak at the connection. Clean away the soapy residue and tighten or refit the 

leaking connection. Make sure the gas is turned off when tightening or refitting the leaking connection. 

Refit the gas cylinder to the hook-and-loop strap. Ensure the cylinder is in an upright position.

Turn the knob fully 

clockwise before fitting 

the regulator

Closed

Open

Summary of Contents for Command-Centre

Page 1: ...02 Page 1 of 20 Zip HydroTap G4 Installation instructions Chilled sparkling model Command CentreTM Filtered chilled and sparkling drinking water for residential kitchens Affix model number label here...

Page 2: ...taps to suit the customer s needs Classic HydroTap G4 range Arc Cube HydroTap G4 range Elite HydroTap G4 range These standalone taps are directly compatible with the G4 Command CentreTM Celsius HydroT...

Page 3: ...ead Step 2 Check for adequate ventilation Section 1 Ventilation 1 1 Ventilation on all models 11 Step 3 Fit the CO2 gas cylinder Section 2 CO2 cylinder and regulator 2 1 2 4 Connect secure and test th...

Page 4: ...er cupboard floor has sufficient strength to support the Command CentreTM when full of water see page 9 for weights Before commissioning Check the Command CentreTM has been installed correctly Check a...

Page 5: ...r residential applications The Zip HydroTap G4 Command CentreTM utilises a conventional refrigerant compressor to chill the water and uses a CO2 gas cylinder to carbonate the chilled water The Command...

Page 6: ...n To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Lifting Take...

Page 7: ...nd CentreTM is rated for 230V 50Hz AC operation Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply The Zip HydroTap G4 Command...

Page 8: ...o that the connection point and the stop cock will not be obstructed when all the undersink units are installed For Zip HydroTap 160 125 160 175 models a 220 240Vac 10A GPO will be required For Zip Hy...

Page 9: ...sparkling models 1x13A 0 35 280 x 405 x 333 30kg Min Max water supply pressure HydroTaps and Mains All in One taps 0 25 MPa 2 5 bar 0 7 MPa 7 bar Chilled and sparkling HydroTap G4 range Chilled spark...

Page 10: ...40V AC 13A socket will be required The Command CentreTM must be installed in accordance with IEE regulations See Technical specification page 9 for power ratings Note Check all cable and hose lengths...

Page 11: ...the cupboard position A2 Where possible air inlet vent and the air outlet vent should be positioned at opposite ends of the same cupboard space 1 1 Ventilation for all models The clearance envelope di...

Page 12: ...upright position 2 2 Connect the regulator Remove the gas cylinder from the strap Make sure the regulator knob is turned fully clockwise to the end stop before fitting Screw the regulator clockwise o...

Page 13: ...eak test to check for gas leaks between regulator and cylinder and between regulator and braided hose Stage 1 1 Turn the gas off 2 Using soapy water applied with a sponge or with a brush cover all of...

Page 14: ...mand CentreTM The blue chilled and white sparkling pipes must be insulated with the sleeving provided CHILLED OUT Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the...

Page 15: ...lope Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the Command CentreTM according to the hose and cable lengths supplied 3 3 Chilled sparkling and mixed hot cold C...

Page 16: ...oning the system may be customised by selecting further options in section G Settings of the user manual Section 4 Commissioning Commissioning Press the MENU button for main menu Press the Install but...

Page 17: ...ter Flush Menu Stop cock operation Have a bucket or similar container not supplied at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation Open the fi...

Page 18: ...ocked Blocked air filter Remove blockage clean filter check user guide Water leak Isolate Mains Water leak Turn off mains water supply call for service Compressor Over Run Compressor too hot Check ven...

Page 19: ...n of the appliance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the app...

Page 20: ...rks of Zip Heaters Aust Pty Ltd Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US510385...

Reviews: