804052UK - Residential chilled and sparkling installation instructions - Sept 2016 - v3.02
Page 17 of 20
Commissioning
•
Press [START] / [STOP] button to start and stop the filter
flush.
•
Open the flush stop cock.
•
Allow at least 10 litres of water to flush through the filter.
•
Once the filter flush is finished, Close the stop cock then
press [STOP] to end filter flush mode.
OPEN Position
CLOSED Position
ON
OFF
G4 HydroTap Filter Flush Menu
Stop cock
operation
Have a bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected
while the filter flush mode is in operation. Open the filter access door on the front of the HydroTap
®
G4 and
the filter cartridge will be exposed. Located to the rear right hand side of the cartridge is a flush line, approx
600mm long and the flush line stop cock. Place the free end of the flush line into the bucket or container (not
supplied).
Note
At first commissioning, the system will select the filter flush screen automatically after CO
2
purge.
4.3 - Filter flush