Instructions. V1.01
Page 4
JULY / 2013
CAUTIONS
• Children should be supervised in order to make sure that they do not play with the appliance.
• The appliance must not be subjected to pressure exceeding 0.6 MPa (6 bar), for
pressures exceeding 0.35MPa (3.5 bar) it is recommended that a pressure reducing
valve be installed.
• The appliance must only be used when correctly installed and in perfect working order.
• The appliance must be installed in a frost-free room and must never be exposed to frost.
•
The appliance must be completely filled with water before being switched on.
• The Aquapoint III is intended for connection to mains supply only. In any other case please
contact Zip on 0845 6 005 005 for advice.
• Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to
observe these instructions.
• It is recommended that an
HE45004
Water Block is fitted in the water supply line to
minimise the potential damage in the event of any leakage.
Packed Contents
Please check that the items below have been supplied in the Heater Unit package.
Wall Bracket
x1
Fixing Screws
x2
Rawlplugs
x2
Expansion Relief Valve(1/2”BSP)
x1
Dimensions
Model
Capacity
(litres)
Dimensions
(mm)
Fixing
Centres
(mm)
A
B
C
D
E
F
AP3/05(OB)
6
376 256 260 100 252 140
AP3/10 (OB)
10
480 350 265 100 378 140
AP3/15 (OB)
15
480 350 310 100 378 140
Accessories
:
AQ1: Temperature and Pressure relief valve.
AQ2: Expansion vessel and Check valve.
AQ3: Combined pressure reducer and line strainer.
AQ4: Thermostatic blending valve complete with 2 check valves.
HE45004: Water block.
D
B
F
E
C
A