Zip AP3/05 Nstallation, Maintenance And User Instructions Download Page 18

 Instructions. V1.01 

Page 16  

JULY / 2013

The Zip appliance you have chosen is precision-built from the finest materials available and 

should give many years of trouble free service.

Certain warranties may be implied by law into your contract with Zip.  

The warranty provided below is additional to these implied warranties and nothing set out 

below shall limit your statutory rights or rights at law.
Zip Heaters (UK) Ltd warrants that, should any part fail within 12 calendar  months of 

installation, that part will be repaired or replaced free of charge by Zip or its Distributor or 

Service Provider, except as set out below, provided the appliance is installed and used strictly 

in accordance with the instructions supplied, and that failure is not due to accident, misuse, 

abuse, unsuitable 

water conditions, or to any alteration, modification or repair by any party 

not expressly nominated by Zip.

No costs are payable by the customer other than any mileage or travelling-time  charges 

incurred by a Zip Service Provider or the cost of removal, cartage and re-installation of any 

component of the appliance if it needs to be returned for repair to Zip or its Distributor.
This warranty does not cover damage resulting from non-operation of the  appliance or 

consequential damage to any other goods, furnishings or property.
Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted or 

modified or which cannot, except to a limited extent, be 

excluded, 

restricted or modified as 

between the owner or user and Zip under the laws applicable.

Furthermore, this warranty does not displace any statutory warranty, but, to the  extent to 

which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited 

at Zip’s option to the replacement of the appliance or  supply of equivalent appliance, the 

payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the 

payment of the cost of having the appliance repaired or the repair of the appliance.

Warranty

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter 

data, specifications and component parts without prior notice.

To ensure you have the latest revision of this instruction manual, please visit www.zipheaters.co.uk 
to download the latest copy.

IMPORTANT: 

No liability is accepted for incorrect use of this product.

The use of this crossed out wheeled bin logo indicates that this product needs 
to be disposed of separately to any other household waste.
Within each of the European Union member countries, provisions have been 
made for the collection and recycling of unwanted electrical and electronic 
equipment.
In order to preserve our environment we ask that you dispose of this product 
correctly. Please contact Zip Customer Service for advice on 0845 6 005 005.

Summary of Contents for AP3/05

Page 1: ...e instructions carefully before commencing installation of this unvented water heater Please leave these instructions with the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way Dereham...

Page 2: ...inside front cover inside back cover...

Page 3: ...nd when correctly fitted to comply with the requirements of the United Kingdom Water Regulations Byelaws Scotland The products are listed under the WRAS Water Regulations Advisory Scheme Water Fitting...

Page 4: ...fitted to the vessel to provide anti corrosion protection for the vessel and the heating element Description Gradual erosion of the anode will occur depending on local conditions and in extreme cases...

Page 5: ...e appliance its wiring and piping must not be modified in any way In case of malfunction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carrie...

Page 6: ...0845 6 005 005 for advice Zip Heaters UK Ltd cannot be held liable for any damages caused by failure to observe these instructions It is recommended that an HE45004 Water Block is fitted in the water...

Page 7: ...pacity 6 Litre 10 Litre 15 Litre Weight kg Full 12 7 18 5 24 8 Weight kg Empty 6 7 8 5 9 8 Heat up time 15 C to 65 C 11 mins 18 mins 32 mins Re heat time 70 vol 7 mins 12 mins 18 mins Heat Loss kWh 24...

Page 8: ...rol knob lens AQ0332 4 Thermostat AQ0333 5 Resettable cut out AQ0334 6 Sacrificial anode 10 15 litre AQ0335 7 Sacrificial anode 5 litre AQ0347 8 Indicator light AQ0336 9 Control knob with spring AQ033...

Page 9: ...2 and AQ3 pressure reducing valve and line strainer see diagrams 2 3 fig2 page 10 6 If required a temperature and pressure relief valve accessory AQ1 can be used with any installation by fitting secur...

Page 10: ...laced unsupported on the floor or cupboard base but if additional support is required securing screws are supplied that locate to the rear of the casing As shown in fig 1 4 Always position the Zip Aqu...

Page 11: ...s Do not use plumbers paste to secure the joints as this can impair the operation of any valves connected to the heater 6 An isolating service valve not supplied should be fitted in the cold water sup...

Page 12: ...1 NEAREST COLD WATER DRAW OFF HOT COLD EXPANSION RELIEF VALVE EXPANSION VESSEL SERVICE VALVE CHECK VALVE PRESSURE REDUCING VALVE DIAGRAM 3 Inlet pressure greater than 0 35 MPa 3 5 bar Using pack AQ2...

Page 13: ...ole switched spur 2 If the cable length is insufficient it is recommended that the entire length of cable is replaced with no joins to the original To replace the cable a a Prise the temperature contr...

Page 14: ...h a water temperature of 55 C is recommended for economical operation while minimising lime scale deposits and thermal losses Note Rotating the temperature control knob varies the temperature over the...

Page 15: ...cated inside the cover DO NOT reset the over temperature cut out until the cause of it s operation has been correctly diagnosed and corrected 4 DO NOT use the water heater if it is suspected of being...

Page 16: ...connect the wire between the anode and the vessel and check that the current between anode and vessel exceeds 0 4mA Ensure that the wire is reconnected afterwards If the current between the anode and...

Page 17: ...the thermal controls when discharge ceases Replace the thermostat if faulty Continuous water discharge from tundish Pressure reducing valve not operating correctly Check with pressure gauge and repla...

Page 18: ...Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner...