background image

Page 6 of 12 

Zip FlushMaster Pearl Installation & Maintenance Instructions - 82902 - January 2012 v1.00

Install Sensor

Position the ceiling sensor not more than 500 mm from the urinal wall. Sensor coverage from a 2700 mm ceiling is 
approximately 2400 x 3600 mm.

For a single stall urinal, position the sensor above the centre of the stall. Position the sensor slots at right angles to the 
urinal wall.

For a double stall urinal, position the sensor midway between the stalls. Position the sensor slots at right angles to the 
urinal wall.

For a triple stall urinal, position the sensor above the centre of all three stalls. Position the sensor slots parallel to the 
urinal wall. For more than three stalls, use additional sensors.

Warning. Do not connect battery or power pack until all plumbing connections are completed. The power must be 
connected last as connection activates the system test mode (see page 8).

To install a ceiling recessed sensor:

 WS004 and 99168, will require a 64 mm diameter hole in the ceiling. 

 WS003; WS006 and WS007 will require a 105mm diameter hole in the ceiling

Use inbuilt clips to fasten sensor housing in place when inserted into hole. (see diag below)

Typical Installation with Ceiling Resessed Sensor 

Urinal wall 
surface

2400 mm

< 500  mm

Two or three 
Stalls

3600 mm

1800 mm

3600 mm

Urinal wall 
surface

< 500  mm

Ceiling 
Sensor

Sensor 
Slots

Ceiling 
Sensor

Sensor 
Slots

2400 mm

1200 mm

One or Two 
Stalls

B

B

A

A

A

A

Step 1. Insert sensor with clips ‘A’  
 

    in the upright position

Step 2 . Ensure clips ‘A’ are in      

 

 

     the folded down position

Summary of Contents for 99168

Page 1: ...Master Pearl Zip FlushMaster Mk 2 41091 Zip FlushMaster Pearl Compact Recessed Sensor Solenoid DC WS004 With 64mm body Water Saver Urinal Flushing System Keeps Urinals Clean Reduces Water Wastage Inst...

Page 2: ...Details 12 99168 Pearl Water Saver Sensor only 64mm body 99021 Zip FlushMaster Cistern Autosyphon 1 00 inch BSP 25 mm 99022 Zip FlushMaster Cistern Autosyphon 1 25 inch BSP 32 mm 99023 Zip FlushMaste...

Page 3: ...ctions Designed for indoor use only do not expose to elements of nature All plumbing connections must be made in accordance with AS3500 Supply pressure 350kPa 700kPa Installation Procedure 1 Set up wa...

Page 4: ...itre discharge capacity Typical Installation with Cistern Typical Installation with Direct Injection Flow restrictor Installation Notes The Restrictaflow must be fitted between the isolating valve not...

Page 5: ...een the cistern water level and the inlet water pipe level to prevent backflow Airbreak Installation The air break must be fitted in a vertical position Fitting in a position other than vertical will...

Page 6: ...r more than three stalls use additional sensors Warning Do not connect battery or power pack until all plumbing connections are completed The power must be connected last as connection activates the s...

Page 7: ...Secure the brown cable into the right hand screw terminal and tighten Secure the blue cable into the left hand screw terminal and tighten Push the plug into the socket on the circuit board positioned...

Page 8: ...is shipped with the following Preset Values Janitorial Flush Set at 12 Hours Delay Time Set at 45 seconds Fill Time Set at aprox 5 seconds Connect Optional Power Pack AC Power Pack product code 99031...

Page 9: ...own Push the button again and the light will change from Green to Red as shown repeat this as many times as required for Delay TIme Each push of the button ads 45 seconds Delay up to a maximum of 30 m...

Page 10: ...s on page 8 and 9 Replace cover on battery holder and replace cover on sensor housing Battery low When the battery voltage becomes low the detection LED on front of unit will flash both Green and Red...

Page 11: ...Reset sensor timer switches Cistern fills or direct inject flushes for only 5 seconds at a time Sensor timers set to test mode Reset sensor timer switches Cistern fills or direct inject flushes for o...

Page 12: ...Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 IPG Z 103 As Zip policy is one of...