background image

Page 10 of 12

Zip Hydroboil - Installation & Operating Instructions - 81419 - January 2004

Single Element 15 Lt & 25 Lt

The single element PCB is factory pre-set to give optimum performance in all
normal installation situations.

For high altitude installations (above 1000mtrs) there is an alternative dip

switch setting. See both settings at left.

Multi Element 40 Lt

The multi element PCB is factory pre-set to give optimum performance in all
normal installation situations.

For high altitude installations (above 1000mtrs) there is an alternative dip
switch setting. See both settings at left.

Note:

When altering the factory pre-set temperature of a multi element PCB it is

important that dip switch No.4. is in the OFF position.

Connecting John Guest Fittings

Single element factory preset.

Single element altitude setting above 1000 mtrs.

Multi element factory preset.

Multi element altitude setting above 1000 mtrs.

Main PCB Settings

Summary of Contents for 11061 Hydroboil

Page 1: ...boiling water 11062 Hydroboil Electronic 15 Litre White 11061 Hydroboil Electronic 15 Litre S S 12062 Hydroboil Electronic 25 Litre White 12061 Hydroboil Electronic 25 Litre S S 04062 Hydroboil Electr...

Page 2: ...Installation Procedures 4 Step 1 Positioning 4 Step 2 Fastening 4 Step 3 Connecting 5 a Plumbing 5 b Venting 5 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Problem Solving 7 Operating Pr...

Page 3: ...the heater under any circumstances without first isolating the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this h...

Page 4: ...ger vessels Minimum clearances for service are 150 mm top 65 mm left and 20 mm right Mark corner position on wall so to position mounting hole template Step 2 Fastening Position mounting hole template...

Page 5: ...Pa a pressure limiting valve must be installed in the cold water supply line We recommend a valve rated at 350 kPa for this application b Venting A vent at the base of the heater must be plumbed to a...

Page 6: ...er is upright Step 5 Commissioning Check previous steps Turn water supply ON check connections for leaks Turn tap handle to the lock down side and leave open until water starts flowing from the outlet...

Page 7: ...a vessel to be filled without holding your hand where it may be affected by steam Pot fill position Cup fill position Symptom Possible Cause Solution Fails to dispense water Water isolating valve tur...

Page 8: ...brought to boiling point and is being maintained normally within 1 C of boiling point During the initial heat up the contents of the boiling chamber may be below boiling point for a period and during...

Page 9: ...Mounting Template Wall template for 15 litre 25 litre 40 litre models 374 15L 25L 499 40L 295 15L 25L 420 40L 591 15L 25L 771 25L 831 40L 188 15L 25L 313 40L EXTERNAL PLUMBING INTERNAL PLUMBING BENCH...

Page 10: ...multi element PCB is factory pre set to give optimum performance in all normal installation situations For high altitude installations above 1000mtrs there is an alternative dip switch setting See bo...

Page 11: ...p kit 13 90536 Fascia lens and actuator kit 14 90494 Meter tube kit 2400 watt 14 90526 Meter tube kit 3000 watt x 2 14 90527 Meter tube kit 3600 watt 15 90502 Tap assembly complete 16 90594 Main PCB k...

Page 12: ...Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damag...