Where there is no singlemode content within the backbone cabling, the choice lies between the re-use of existing
549
multimode optical fibre cabling (see 4.3.1.2) and the installation of additional multimode or singlemode backbone cables
550
(see 4.3.1.4).
551
552
553
SMF optical fibre cable: building backbone
Industry-standard SMF cord
Duplex LC - backbone panel
Zinwave SMF TO cable
Optical fibre management
Fusion spliced industry-standard SMF pigtails
ZinWave
Termination Panel
Backbone
Termination Panel
554
Figure 4-5: Re-use of existing singlemode optical fibre backbone cabling at an FD/HC via patching
555
556
557
Zinwave SMF TO Cable
Optical fibre management containing fusion splice joints
SMF optical fibre cable: building backbone
ZinWave
Splice Panel
558
Figure 4-6: Re-use of existing singlemode optical fibre backbone cabling at an FD/HC via splicing within a panel
559
560
4.3.1.3
Re-use of existing multimode backbone cabling
561
If there are adequate numbers of unused (or reassignable) multimode optical fibres in the building backbone cabling then
562
their use for the ZinWave 2700 DAS will require, as shown in Figure 4-7:
563
•
a crossconnection using the appropriate ZinWave hi-conn “patch cord” between the and the ZinWave Termination
564
Panel in the FD/HC;
565
•
the re-termination (at both ends) of the available optical fibres in the existing backbone panel using appropriate hi-
566
conn pigtails of Table 3-8;
567
•
the replacement of the backbone panel adaptors (at both ends) with their singlemode equivalents.
568