ZINWAVE 2700
DISTRIBUTED ANTENNA SYSTEM
-
INSTALLATION AND TECHNICAL MANUAL
ZINWAVE 2700 DAS - INSTALLATION AND TECHNICAL MANUAL
Page 13
CONVENTIONAL MULTIMODE OPTICAL FIBRE INSTALLATION
AMENDED MULTIMODE OPTICAL FIBRE INSTALLATION FOR ZINWAVE 2700 DAS
ZinWave 2700 Hub Unit
ZinWave 2700 Equipment Cord
ZinWave 2700 Pigtail
ZinWave 2700 Pigtail
ZinWave 2700 Pigtail
ZinWave 2700
Patch Cord
Industry-standard SMF adaptors
Industry-standard SMF adaptors
Industry-standard MMF adaptors
Industry-standard MMF adaptors
Industry-standard MMF field terminations (or pigtails)
289
290
Figure 3-4: ZinWave 2700 DAS installation on multimode optical fibre
291
292
293
3.6
Singlemode optical fibre terminations and cords
294
There are no ZinWave-specific requirements for the installation of the 2700 DAS using singlemode optical fibre. Industry
295
standard equipment cords and patch cords may be used.
296
297
298
3.7
Telecommunication Outlet (TO) connectivity
299
Each ZinWave 2760 or 2776 Antenna Unit is connected to a Telecommunications Outlet (TO) which terminates the
300
wireless application overlay cabling.
301
302
In order to simplify the installation of the TO and the cabling to the TO, the ZinWave components listed in Table 3-9
303
should be used.
304
305
The TO Closure is designed to allow the connection of optical fibre cabling and, where required, remote power via
306
“Power over Ethernet” to one or two ZinWave 2760 or 2776 Antenna Units.
307
308
Each TO Closure should be located in a position to allow a simple connection to the ZinWave 2760 or 2776 Antenna Unit
309
using the appropriate equipment cord of Table 3-8 (for attachment to multimode optical fibre cabling) or a industry-
310
standard singlemode optical fibre cord i.e. not required to be a ZinWave product (for attachment to singlemode optical
311
fibre cabling).
312
313
The TO Closure has glanded ports for two LC-Duplex connectors and two shrouded IEC 60603-7 sockets. The required
314
number of optical ports shall be fitted with industry-standard singlemode optical fibre adaptors following the installation of
315
the TO Closure.
316