ZINWAVE 2700
DISTRIBUTED ANTENNA SYSTEM
-
INSTALLATION AND TECHNICAL MANUAL
ZINWAVE 2700 DAS - INSTALLATION AND TECHNICAL MANUAL
Page 35
920
NOTE:
it may be possible to avoid the use of Zinwave hi-conn pigtails if the multimode optical fibre is of the laser optimised
921
type specified in the ANSI/TIA/EIA-568-B series standards or of Category OM3 specified in EN 50173-1 and ISO/IEC
922
11801. However, this decision should only be made following agreement with appropriate ZinWave personnel.
923
924
5.1.4.2
Singlemode optical fibre cables
925
The termination of all singlemode optical fibres to be used by the ZinWave 2700 DAS shall be via the fusion splicing of
926
industry-standard pigtails. The adaptors shall be SMF variants of the relevant connector style.
927
928
5.1.4.3
Balanced cables for the provision of remote power to the ZinWave 2760 or 2776 Antenna Units
929
The pin-pair allocation of the cable at the TO Closure shall be that of the cables at the balanced cabling panel. This may
930
be either T568A or T568B (defined in ANSI/TIA/EIA-568-B series standards) in accordance with the pin-pair allocation
931
elsewhere in the premises.
932
933
The connecting hardware at the balanced cabling panel at the FD/HC shall be in accordance with Category 5e of
934
ANSI/TIA/EIA-568-B-2 or Category 5 of EN 50173-1 (equivalent to Category 5 specified in ISO/IEC 11801:2002).
935
936
5.1.5
Cords
937
5.1.5.1
Multimode optical fibre cords
938
Where ZinWave 2700 DAS Hub and Antenna Units are connected to multimode optical fibre interfaces it is necessary to
939
use ZinWave 2700 equipment cords listed in Table 3-8. These duplex cords feature an offset launch in the “launch” leg
940
and must be connected in the correct orientatIon.
941
942
The connection between multimode optical fibre interfaces for the ZinWave 2700 DAS shall be made via ZinWave hi-
943
conn cords as detailed in Table 3-8.
944
945
NOTE:
it may be possible to avoid the use of Zinwave equipment cords and patch cords if the multimode optical fibre is of the
946
laser optimised type specified in the ANSI/TIA/EIA-568-B series standards or of Category OM3 specified in EN 50173-1
947
and ISO/IEC 11801. However, this decision should only be made following agreement with appropriate ZinWave
948
personnel.
949
950
5.1.5.2
Singlemode optical fibre cords
951
The connection of singlemode optical fibre interfaces for the ZinWave 2700 DAS shall be made via industry-standard
952
cords.
953
954
5.1.5.3
Balanced cables for the provision of remote power to the ZinWave 2760 or 2776 Antenna Units
955
The cords shall be in accordance with Category 5e of ANSI/TIA/EIA-568-B-2 or Category 5 of EN 50173-1 (equivalent to
956
Category 5 specified in ISO/IEC 11801:2002).
957
958
959
5.2
Inspection and testing of installed optical fibre cabling
960
ISO/IEC 14763-3 contains the full set of inspection and test methods for installed optical fibre cabling.
961
962
963