INSTALLATION AND OPERATING INSTRUCTIONS:
startZ Universal Robots
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
10
EN / 2020-11-30
DDOC01095 / 0
7.3 Installing the mechanical system
7.3.1 Installing GEH6000IL
Example representation of the gripper installation:
The gripper is mounted to the robot using the
base and adapter plate.
Ö
10.25 Nm (4x M6 mounting screws
4
/
adapter plate
2
)
Ö
3.0 Nm (2x M4 gripper/adapter plate
2
)
Ö
3.0 Nm (1x M4 gripper finger)
The following work steps must be observed
during installation:
►
Position the adapter plate
2
on the
gripper
1
.
Ö
The alignment is carried out using the
centering pin
3
.
►
Affix the adapter plate
2
on the robot using
the mounting screws
4
.
►
Position the gripper
5
on the adapter plate
2
.
Ö
The alignment is carried out using the two
centering pins
6
.
►
Fix the gripper
5
with the mounting screws
7
to the adapter plate
2
.
There is the option of mounting the gripper
fingers in two positions.
This means that the gripper can be used for
inside and outside gripping.
Ö
The gripper fingers must always be mounted
mirroring each other.
1
2
3
4
5
6
7