12.2 Emergency release of GED6000IL
CAUTION
Risk of injury due to uncontrolled movement
Risk of injury in the event of uncontrolled movement of the product when the power supply is connected.
►
Switch off the power supply to the product before all work.
►
Secure the power supply against being switched on unintentionally.
►
Check the product for any residual energy that may be present.
CAUTION
Risk of injury in case of non-compliance
►
Disconnect the actuator voltage before pressing the emergency release.
The product features an emergency release that can be mechanically opened with an Allen key in the event of a power
failure.
►
Switch off the power supply.
►
Remove the protective cap to reach the
emergency release.
►
Actuate the emergency release with the
corresponding Allen key.
•
Turning counterclockwise opens the
jaws (toward the BasePosition).
•
Turning clockwise closes the jaws
(toward the WorkPosition).
►
When opening the gripper fingers, make
sure that the workpiece in the product is
secured.
cn
cm
Installation size
Wrench size [mm]
GED6040IL-03-A
2.5
GED6040IL-31-A
2.0
GED6140IL-03-A
3.0
cm
Protective cap
cn
Allen key
INFORMATION
►
Carry out another reference run after any emergency release.
►
Please contact Zimmer Customer Service if you have any questions.
13 Gripping force charts
INFORMATION
►
You can find information on our website.
►
Please contact Zimmer Customer Service if you have any questions.
14 Error diagnosis
Error code
Error
Possible cause
Measure
0x0000
Device is ready for operation.
-
-
0x0001
Motor controller is switched off.
• Motor controller has not yet
been activated.
•
Motor controller has been
switched off.
• Motor controller was
switched off for device
protection.
►
Switch on the motor
controller.
0x0100
Actuator power supply is not
present or is too low.
• Actuator power supply is not
connected
• Actuator power supply is not
sufficient
•
Cable break
•
STO input circuit is
interrupted.
►
Check the actuator power
supply.
►
Switch on the STO input
circuit.
0x0101
Temperature above maximum
permitted temperature.
•
Ambient temperature is too
high.
•
Overload of the products.
►
Provide sufficient ventilation/
cooling/connection.
►
Check that the product
moves freely.
0x0102
Max. permitted temperature
undershot.
•
Ambient temperature is too
low.
►
Provide an adequate
operating temperature.
0x0206
Motion task cannot be executed
(CRC error).
• Internal error
►
Apply the process data via a
handshake.
►
Please contact Zimmer
Customer Service.
0x0300
ControlWord is not plausible.
•
Multiple bits were set in the
ControlWord.
►
In the ControlWord, check
that only one bit is set.
0x0301
Positions are not plausible.
•
Transmitted positions
(TeachPosition, BasePo-
sition, ShiftPosition, WorkPo-
sition) are not plausible.
•
Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0302
GripForce is not plausible.
•
Transmitted GripForce is not
plausible.
•
Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0303
DriveVelocity is not plausible.
•
Transmitted DriveVelocity is
not plausible.
•
Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0304
PositionTolerance is not
plausible.
•
Transmitted PositionTo-
lerance is not plausible.
•
Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0305
Position measuring system not
referenced.
• Position measuring system
is not referenced.
•
A reference run is being
performed.
►
Reference the product.
►
Wait until the reference run