11.3 EtherCAT
NOTICE
Commissioning the product depends on the configuration of the drive control unit and can therefore vary.
This section uses the commissioning of the product of the DES190 installation size as an example.
►
Do not use the example as a programming template.
►
For more information, refer to the "Function of the function block” section.
11.3.1
Configuring the drive control unit
►
Connect the drive control unit to the computer using its network interface.
►
Search for the correct drive control unit using the
IndraWorks Ds
software, see section “Setting the IP address”.
►
In the
Configuration
menu, click
Load
.
Ö
The
Load Parameters
window opens.
►
Enable the option field of the desired
parameter set.
►
Click the
Load
button.
Ö
The
Load Parameters
window closes.
►
In the navigation pane, click
Master
Communication
.
Ö
The
Master Communication Basic Settings
tab is displayed in the window.
►
In the
Active Protocol
drop-down menu,
select the communication type for the
control system.