11.2.5 Referencing the motor encoder
INFORMATION
While in the
Module
operation mode, the product has a continuous travel range.
The travel range can be limited in degrees via the
IndraWorks Ds
software.
►
In the navigation pane, click
Motor, Brake,
Measurement Systems
.
►
Click
Motor encoder
.
►
Click
Motor Encoder Position reference
.
►
Enter the reference measurement in the
Reference measurement
field.
►
Disable the release for the drive control unit.
►
Click the
Set Absolute Position
button.
Ö
The product references itself to the entered
reference measurement.
►
Move the product in Easy Startup mode
after the reference position has been
adopted.