3.8 REPLACEMENT PARTS

The following is a list of field replacement parts that can be 

ordered from Zimmer. To obtain parts or additional informa-

tion regarding your unit, write or phone:
MAIL: 

Zimmer Orthopaedic Surgical Products 

200 West Ohio Avenue 

Dover, Ohio 44622 U.S.A. 

PHONE:  330-343-8801 or 

800-321-5533

You can also contact your local Zimmer distributor. To en-

sure prompt service, please include the following informa-

tion with your order:
Model Number 

Serial Number 

Description of Part 

Part Number (If known) 

Quantity Desired 

Shipping Address 

Shipping Means (If any)

7885tbl03.01

7/15/99, 10:58 AM

We strongly recommend that all repairs be done by properly trained staff.

Zimmer Replacement
Part Number

Description

62-1109-001-00

Valve Manifold,
without valves

62-1112-001-00

Pump Muffler, without
tubing

60-2000-000-03

Pump, without tubing

62-1117-001-00

3/16 in. (.5 cm)
Y-Connector

62-1119-001-00

Reservoir, 20 cubic in.
(328 cm

3

)

60-2000-000-06

Valve, 24 V Clippard:
slow inflate/deflate

60-2000-000-07

Valve, 24 V Burkert:
fast inflate/deflate

60-2000-000-08

Fuse, 500 mA
5 x 20 mm

62-1129-001-00

Contol Panel,
13 touch-switch

62-1131-001-00

Alarm Silence Switch
without lamp

62-1132-001-00

Alarm Silence Lamp

62-1133-001-00

Alarm Silence Lens,
red

62-1134-001-00

Feet, without screws

60-2000-000-14

Power  Supply

60-2000-000-15

CPU Board

62-1137-001-00

Fuse Drawer,
1/4 in. x 1 1/4 in.
(.6 x 3.2 cm)

62-1138-001-00

Fuse Drawer,
5 x 20 mm

62-1160-001-00

Molex 8-pin connector

Zimmer Replacement
Part Number

Description

62-1162-001-00

Battery Jumper

62-1163-001-00

Battery Harness

62-1164-001-00

Power Entry Harness

62-1165-001-00

Power Entry Jumper,
Blue

62-1166-001-00

Power Entry Jumper,
Brown

62-1167-001-00

Power Entry Harness
Ground

62-1168-001-00

Alarm Silence Harness

62-1169-001-00

Speaker Harness

62-1175-001-00

8 Ohm Speaker

62-1179-001-00

1 Amp Time Delay
1 1/4 in. (3.2 cm) Glass
fuse

62-1180-001-00

Pump Gasket

60-4000-821-00

Crimp Terminal for
Molex Connector

62-1389-001-00

Molex 2-pin
Connector

62-2360-001-00

Pole Clamp Knob

60-7000-027-00

12 V,  2.3 Amp Hour
Battery
Power Entry Module

62-1184-001-00

Gray Power Cord

62-1192-001-00

Bulk Power Supply

Harness

Summary of Contents for A.T.S. 2000

Page 1: ...Operator Service Manual A T S 2000 TOURNIQUET SYSTEM REF 60 2000 101 00...

Page 2: ...EDIES In no case shall Zimmer Inc be liable for any special incidental or consequential damages whether based on breach of warranty or other legal theory Some states do not allow limitations on warran...

Page 3: ...ns 6 2 3 2 Volume Selection 7 2 4 Controls Indicators and Connectors 7 2 5 Single Cuff Operation 8 2 6 Dual Cuff Operation 9 2 7 Bier Block Cuff Operation IVRA 9 2 8 Alarm Conditions 9 2 8 1 Pressure...

Page 4: ...ssis From Rear Case 24 8 10 Separating Chassis 25 11 CPU Board 26 12 Power Supply Board 27 13 CPU Schematic Sheet 1 of 3 ENCLOSED 14 CPU Schematic Sheet 2 of 3 ENCLOSED 15 CPU Schematic Sheet 3 of 3 E...

Page 5: ...s time alarm low battery voltage hardware failure For certain types of equipment mal functions the unit will also display error messages for certain equipment malfunctions that identify the cause of e...

Page 6: ...Skin grafts in which all bleeding points must be readily distinguished Compromised vascular circulation e g peripheral artery disease Diabetes mellitus The presence of sickle cell disease is a relativ...

Page 7: ...ing effect exerted by an unpressurized cuff and its padding if used which prevents venous return at the beginning of the operation 2 By blood remaining in the limb because of insufficient exsangui nat...

Page 8: ...cuff line with connector and second cuff line with connector into the reservoir sense ports See Fig 1 m Apply 250 mm Hg of pressure to the reservoir sense ports The display should read 250 3 mm Hg n...

Page 9: ...etting touch switch or The TIME display will display the time setting with an asterisk in the far left digit The asterisk helps the operator identify that the data being displayed is the set point dat...

Page 10: ...uet can be fitted around the wrist Apply a leak free tourniquet cuff smoothly without wrinkles The valve port and hose connections should be placed so that the hose will not be kinked when the limb is...

Page 11: ...Table 2 1 The appropriate actions indicated are based on the most probable causes and should only be used as a guide Other causes of alarm conditions may indicate a need for other actions In addition...

Page 12: ...ESSURIZED DURING POWER UP This will occur if for example the unit is turned off and back on without deflating the cuff STEADY HIGH PITCH CUFF INFL LIT If a cuff pressure is 50 mm Hg or greater at the...

Page 13: ...OF CALIBRATION OR CAL VALVE MALFUNCTION CAL2 FAIL STEADY HIGH PITCH LIT SECOND CUFF OUT OF CALIBRATION OR CAL VALVE MALFUNCTION CALR FAIL STEADY HIGH PITCH LIT RESERVOIR OUT OF CALIBRATION OR CAL VALV...

Page 14: ...AC power or during patient transport The Windowing Watch Dog Circuit Safety Processor is a hardware circuit that monitors the timing signal generated by the microprocessor as well as valve states and...

Page 15: ...nd 475 13 Remove source pressure then disconnect the calibra tion connecting hose from both sense ports 14 Return the set points to zero by pressing the time touch switch 3 times for each cuff 15 Pres...

Page 16: ...aintenance is required of the battery charg ing circuit The life of the batteries depends on the type of service and the storage method Battery replacement will need to be more frequent with continued...

Page 17: ...nabled TP11 5 V 0 5 V 5 V Supply TP12 5 V 0 V 0 5 V 50 mV 5 V Nominal 0 V when depressing ON STANDBY switch on membrane panel TP13 V Common 50 mV Bulk Supply Common TP14 4 5 V 0 V 1 V 50 mV 0 V if Saf...

Page 18: ...ill not inflate a Touch Switch Panel connector not properly plugged into P9 b Tubing inside unit may be pinched or improperly connected c Valve s stuck d Pump not properly plugged into P10 2 Cuff s wi...

Page 19: ...ngs b Leak in valve manifold c Transducer not working TP29 Voltage will vary with pressure 0 25 to 4 V CPU Board 13 Valve fail alarm message a Faulty valve driver b No power to valves TP17 CPU Board T...

Page 20: ...07 Valve 24 V Burkert fast inflate deflate 60 2000 000 08 Fuse 500 mA 5 x 20 mm 62 1129 001 00 Contol Panel 13 touch switch 62 1131 001 00 Alarm Silence Switch without lamp 62 1132 001 00 Alarm Silen...

Page 21: ...cm 60 7500 005 30 in 76 cm x 4 125 in 10 5 cm 60 7500 006 34 in 86 cm x 4 125 in 10 5 cm 60 7500 007 42 in 107 cm x 4 125 in 10 5 cm A T S Contour Cuff Dual Port Single Bladder 60 7500 008 42 in 107...

Page 22: ...f 60 7400 002 Contour Arm Cuff 60 7400 003 Contour Thigh Cuff 60 7400 004 Lower Leg Cuff A T S Low Pressure Cuff Dual Port Dual Bladder 60 7400 010 Cylindrical Arm IVRA Cuff 60 7400 011 Contour Arm IV...

Page 23: ...y A Reservoir Sense Ports B Main Cuff Sense Port C Second Cuff Sense Port D Calibration Hose Assembly E Calibrated mmHg Pressure Meter minimum range of 0 to 700 mmHg F Pressure Regulator 0 to 700 mmHg...

Page 24: ...ON STANDBY I O Touch Switch B PRESSURE SETTING Touch Switches C TIME SETTING Touch Switches D INFLATE DEFLATE Touch Switches E ALARM SILENCE Switch F PRESSURE Displays G TIME Displays H AC Indicator L...

Page 25: ...23 3 Block Diagram...

Page 26: ...from Rear Case 1 Remove Pole Clamp knob Removing Chassis from Rear Case 2 Remove Rear Cover Screws Removing Chassis from Rear Case 3 Remove 4 Feet and Screws Removing Chassis from Rear Case 4 Slide F...

Page 27: ...25 8 9 10 Separating Chassis 1 Remove top 2 screws Separating Chassis 3 Access to all components Separating Chassis 2 Remove Recessed Bottom 3 screws...

Page 28: ...26 11 CPU Board...

Page 29: ...27 12 Power Supply Board...

Page 30: ...manual Electrical Hazard Year of manufacture Replace fuse as marked Conformity Marking of the Council of the European Community T V Product Service Munich Germany UL Classification Mark Medical Equipm...

Page 31: ...initions 17 WARNING A T S WILL NOT DEFLATE CUFF IN STANDBY MODE MEDICAL EQUIPMENT WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601 1 CAN CSA C22 2 NO 601 1 A...

Page 32: ...Revised 02 05 1996 2005 Zimmer Orthopaedic Surgical Products Printed in U S A 62 2000 101 00 Zimmer Orthopaedic Surgical Products 200 West Ohio Avenue P O Box 10 Dover Ohio U S A 44622...

Reviews: