Z8018x
Family MPU User Manual
166
UM005004-0918
These devices require connection with the Z8X180 synchronous E clock
output. The speed (access time) required for the peripheral devices are
determined by the Z8X180 clock rate. Table 24, and Figure 67 through
Figure 70 define E clock output timing.
Wait States are inserted in Op Code fetch, memory read/write, and I/O
read/write cycles which extend the duration of E clock output High.
During I/O read/write cycles with no Wait States (only occurs during on-
chip I/O register accesses), E does not go High.
Table 24. E Clock Timing in Each Condition
Condition
Duration of E Clock Output High
Op Code Fetch Cycle
Memory Read/Write Cycle
T2 rise - T3 fall
(1.5 Phi + nw x Phi)
I/O read Cycle
1st Tw rise - T3 fall
(0.5Phi + nw x Phi)
I/O Write Cycle
1st Tw rise - T3 rise
In
w
x Phi)
NMI Acknowledge 1st MC
T2 rise - T3 fall
(1.5 Phi)
INT0 Acknowledge 1st MC
1st Tw rise - T3 fall
(0.50 + nw x Phi
)
BUS RELEASE mode
SLEEP mode
SYSTEM STOP mode
Phi
fall - Phi
fall
(2 Phi or 1 Phi)
Note: nw = the number of Wait States; MC: Machine Cycle