Key Values
Step Size
This setting is used to change the microstep resolution of the controller from anywhere between full and
1/256 microstep resolution. For more information on the right microstep resolution for your project, please
visit
Input Value (enter in software)
Microstep Resolution
0
Full step
1
Half step
2
Quarter step
3
1/8 step
4
1/16 step
5
1/32 step
6
1/64 step
7
1/128 step
8
1/256 step
Interpolate
The interpolate setting is used with a step input to determine whether the motor will operate at the step
setting included
Interpolate Value (enter in software)
Setting
0
Motor will run at the microstep resolution
1
Motor will interpolate the microstep to 1/256 for smoother
operation (useful for running with step inputs)