Holding Current
The holding current setting is used to set a holding current for the motor. This is used to enable the motor
to hold itself in a certain position at 0rpm. The values for holding current are exactly the same as the
current settings above. As with the current above, it is important to make sure the settings for this are
acceptable for the motor you choose. Setting this too high will overheat and ultimately damage the motor
and controller.
PLEASE NOTE
–
HOLDING CURRENT WILL ONLY BE APPLIED AT 0 RPM
–
IT WILL NOT FUNCTION IF THE
CONTROLLER IS NOT ENABLED.
Set RPM
This input will set a value in RPM and accepts any value between 0 and 2000. Please note, the controller
does not accept decimal places.
Acceleration & Deceleration Scalar
This setting accepts a value between 0 and 100 for acceleration, and between 0 and 100 for deceleration.
100 will adjust the speed in the fastest time, 1 will make a slow change to the speed. This enables you to
directly control the acceleration and deceleration in a range of situations. Whenever, the motor changes
speed or direction it will reference the acceleration and deceleration values and operate accordingly.