13
Zikodrive Motor Controllers are a product of Round Bank Engineering Ltd
Floor 2, Clifton Warehouse, Sowerby Bridge, West Yorkshire, HX6 2BY
–
www.zikodrive.com
- +44 (0) 1422647177
Current Setting
This setting will determine the main running current for the controller. Take care to match this to the
motor you are using. Setting this value too low can limit the performance of the motor. Setting it too high
can risk overheating and damaging the motor. Check your motor datasheet for guidance on this and
contact us if you are not sure on the correct setting.
Input Value (enter
in software)
Currrent Setting (IRMS)
Current Setting (Peak A)
0
0.04
0.06
1
0.08
0.12
2
0.13
0.18
3
0.17
0.24
4
0.21
0.30
5
0.25
0.36
6
0.30
0.42
7
0.34
0.48
8
0.38
0.54
9
0.42
0.60
10
0.46
0.66
11
0.51
0.72
12
0.55
0.78
13
0.59
0.84
14
0.63
0.91
15
0.68
0.97
16
0.72
1.03
17
0.76
1.09
18
0.80
1.15
19
0.84
1.21
20
0.89
1.27