background image

20

3PCLIOBIM430

 

 

Displaying Special Statuses 

The corresponding heater display alternates between two characters depending on the status.

Event

Heater 

status

Start

conditions

End

conditions

Action

Heater

Display fore 

(1 sec.)

Heater 

Display back 

(1 sec.)

Priority

Heater with residual 

heat

Off

Heater 

Temperature > 50ºC

Heater

Temperature < 40ºC

----------

‘H’

‘H’

3

Heater without pan

On

No pan or not suitable 

pan over the heater

Heater Off

In 1 minute 

Heater off

‘Power’

‘υ’

1

Induction generator 

over temperature

Off

Heat sink

Temperature > 90ºC

Heat sink

Temperature < 80ºC

----------

‘  ’ or ‘H’

‘c’

2

Induction generator 

over temperature

On

No power is 

delivered to 

the heater

‘Power’

 

Errors/Alarms 

The corresponding heater display alternates between two characters depending on the Error.

APPLIANCE ERRORS

Event

(Visualization Priority Order)

Description

Action

End

All Heater Displays

(fore 0.5 sec./ back 0.5 sec)

FalloKeyOnOffEmitter

Security Key Error

App Off (*)

----------

FA

FalloKeyOnOffReceiver 

Security Key Error

App Off (*)

----------

FC

FalloNtcShort

Touch NTc Error

App Off (*)

----------

FE

FalloNtcOpen

Touch NTc Error

App Off (*)

----------

FP

FalloOverTemp

Touch NTc Error

App Off (*)

T < 90ºC

Fc

FalloEepromChecksum

Eeprom Checksum Error

App Off (*)

----------

FH

FalloAdc

Security Key Error

App Off (*)

----------

FJ

FalloSw 

Software Error

App Off (*)

----------

F0

FalloAmbientLight

Keyboard Error

App Off (*)

Light Condition

FL

FalloDivisor

Security Key Error

App Off (*)

----------

FU

FalloTestLedOnOff

OnOff Led Error

App Off (*)

----------

Fd

FalloTetGroupSelection

Keyboard Error

App Off (*)

----------

Fb

 

(*)  All heaters switched Off and locked 

 

 

HEATER ERRORS

Event

(Visualization Priority Order)

Description

Action

End

Heater Display

(fore 0.5 sec./ back 0.5 sec)

FalloComunicaciones

Communication Error

Induction Heaters Off(**) Comm. OK

F5

FalloNtcFocoShort

Induction Heater Ntc Error

Heater Off(**)

Serial Comm.

F1

FalloNtcFocoOpen

Induction Heater Ntc Error

Heater Off(**)

Serial Comm.

F2

FalloNtcFoco

Induction Heater Ntc Error

Heater Off(**)

Serial Comm.

F7

FalloNtcGeneradorShort

Induction Ntc Error

Generator Off (***)

Serial Comm.

F3

FalloNtcGeneradorOpen

Induction Ntc Error

Generator Off (***)

Serial Comm.

F4

FalloNtcGenerador

Induction Ntc Error

Generator Off (***)

Serial Comm.

F8

FalloNoRedGenerador

Induction Error

Generator Off (***)

Serial Comm.

F6

FalloOverLoadGenerador

Induction Error

Generator Off (***)

Serial Comm.

F9

 (**) Heater switched off and locked
(***) Generator Heaters switched off and locked

Summary of Contents for CIS 029.45 WX

Page 1: ...uso INDUCTION GLASSCERAMIC COOKTOP User instructions ELEKTRO GLASKERAMIK INDUKTIONS KOCHFELD Montage und Gebrauchsanweisung PLANO INDUCCION VIDRIOCERAMICA Manual de utilizaci n TABLE INDUCTION VETROCE...

Page 2: ...D Fig C Fig E 2 mm 30 mm 54 mm 40 mm 54 mm L1 L2 N 220 240V 4 3 2 1 2N AC 380 415V L1 L2 L3 220 240V 220 240V 4 3 2 1 3 AC 220 240V L1 N 220 240V 4 3 2 1 1N AC 220 240V L1 L2 220 240V 4 3 2 1 2 AC 22...

Page 3: ...contenuto del presente libretto in quanto fornisce importanti indicazioni riguardanti la sicurezza di installazione d uso e di manutenzione Conservare il libretto per ogni ulteriore consultazione Tutt...

Page 4: ...ents with a rough base to avoid scratching the thermal surface of the top Averyimportantfactorininductioncookingisthedimension of the pot compared to the plate used Fig 7B The cooking zones allow the...

Page 5: ...en um nicht die Glaskeramik zu verkratzen Die Kochzonen d rfen nicht aufgeheizt werden ohne dass ein gef lltes Kochgeschirr darauf steht Nichts direkt auf der hei en Kochzone ohne Kochgeschirr braten...

Page 6: ...tenido de este libro que le proporcionar importantes instrucciones en cuanto a la seguridad de instalaci n uso y mantenimiento Conservar el manual para cada ulterior consulta Todas las operaciones rel...

Page 7: ...5 mm 80 mm 210 mm 130 mm TABLE VETROCERAMIQUE Notice d utilisation CARACT RISTIQUES G N RALES Lire attentivement le contenu du pr sent livret tant donn qu il fournit d importantes indications concerna...

Page 8: ...14 15 3PCLIOBIM430 3PCLIOBIM430 145 mm 80 mm 210 mm 130 mm 8 F F E B A D C A ONN OFF D F 10 8 10 OFF 1 9 10 9 9 E 50 1 2 3 5 2 3 6 7 7 h h 60 1 4 1 4 RU 2 3 1 8 10 9 3 9 2002 96 WEEE...

Page 9: ...17 3PCLIOBIM430 3PCLIOBIM430 60 C 1 1 4 4 2 25mm 3 5 50 C 3 9 6 7 7 160 90 180 200 120 210 FF GR 9 8 F F E B A D C A ON OFF C D F 8 10 9 8 1 9 BOOSTER booster 10 10 9 booster 9 50 C 30 C 1 2 3 1 8 10...

Page 10: ......

Page 11: ...r App Off FP FalloOverTemp Touch NTc Error App Off T 90 C Fc FalloEepromChecksum Eeprom Checksum Error App Off FH FalloAdc Security Key Error App Off FJ FalloSw Software Error App Off F0 FalloAmbientL...

Reviews: