Block Diagram 

– Zigen ZIG-SW42 

 
 

General Operation 

 

SW42 is the ultimate in high-bandwidth UHD switchers. With a full 600 MHz pixel 
clock the SW42 support high bandwidth sources and displays. Additionally, the 
SW42 supports HDCP 2.2 copy protection so you can be sure your customer is 
able to view the latest 4K UHD content 

– either protected (movies) or computer 

content (un-protected). 
 
Basic connections are 4 HDMI 2.0 sources (or below) and one HDMI output to 
the display or projector. There is a SPDIF port that de-embeds audio from the 
currently selected input and routes it to your audio matrix or multi-zone amplifier. 
Additionally, with the SW42 there is a 100 meter HDBaseT port for long distance 
runs. Note HDBaseT is limited to 4K/60 4:2:0 8-bit. 
 
Advanced EDID management is available through a combination of the 4-pin 
dipswitch and WebOS. 15 EDID tables are available, plus you can load custom 
EDID tables. Or, leave the SW42 in the default mode and it will pull the EDID 
from the connected/selected display. By being able to manage the EDID and 
HPD (Hot Plug Detection) you can speed up switching in mixed format systems. 
 
Control the SW42 via the supplied remote control (IR 

– to built-in sensor or run 

an IR receiver to the 3.5mm IR jack). You can also control the SW42 via 3

rd

 party 

control, RS-232, LAN (WebOS/Telnet), or via the input selector switch on the 
front panel. 
 
 

DIP Switch Settings 

 

DIP 1: EDID 
 
OFF (UP): As a default the downstream EDID is copied and used from output 
port 1. 
 

While DIP 1 is OFF (UP) DIP 2 & 3 are active as follows: 

 
DIP 2: (OFF/UP) audio according to downstream capabilities 
DIP 2: (ON/DOWN) audio is restricted to 2-channel regardless of downstream 
EDID. 
DIP 3: (OFF/UP) audio according to downstream capabilities. 

Summary of Contents for ZIG-SW42

Page 1: ...zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 Zigen SW42 HDMI 2 0 UHD 600 MHz 4x1 Switch w HDCP 2 2 WebOS Mirrored Long Distance HDBaseT 100M Port ZIG SW42 USER MANUAL Ver 1 0 ...

Page 2: ...NUAL Table of Contents Copyright and Trademark 3 Introduction 4 Package Contents 4 Features 4 Specifications 5 Block Diagram 8 General Operation 9 Dip Switch Settings 10 Remote Control 12 WebOS 13 Commands 16 Warranty 18 ...

Page 3: ...the registered trademarks referred to this manual are belonging to their respective companies Before You Begin Follow all instructions marked on the device during using Do not attempt to maintain the device by yourself any faults please contact your vendor Provide proper ventilation and air circulation and do not use near water It is better to keep it in a dry environment The system should be inst...

Page 4: ...gle CAT5e of higher SW42 also routes Ethernet and is compliant with the entire Zigen ecosystem of products by routing network commands and control in receiver nodes Typical Applications Classrooms Boardrooms Conference rooms for switching UHD content sources via multiple control options 3rd party controllers WebOS simple remote or front panel buttons High end home theaters for showing UHD 2 0 cont...

Page 5: ...mpliant Specifications Video Bandwidth HDMI 18 GBP sec HDBaseT 10 2 GPBS Max Video Resolutions All SMPTE VESA in HDMI 2 0 Specification Max SMPTE UHD 4096x2160P60 RGB 4 4 4 8 bit Max for HDBaseT port is 2160P60 4 2 0 8 bit HDBaseT CAT limitation Color Space RGB YUV Color Bit Depth 8 bit 10 bit 12 bit 16 bit per pixel Note Resolution and video bandwidth limited ex 2160P60 RGB or 4 4 4 8 bit would u...

Page 6: ...olby TrueHD and DTS HD Master SPDIF Up to Dolby Digital DTS 5 1 Audio Sampling Rates Up to 1536 KHz Distance HDMI Up to 5M 4K HDBaseT Up to 100M at 4K 60 4 2 0 8 bit HDCP 2 2 1 4 or None CEC Pass through Connections 4 x HDMI type A HDMI Input 1 x HDMI type A HDMI Output 1 x RJ45 HDBaseT 100M Port 1 x SPDIF Digital Audio Output 1 x RJ45 LAN Port for TCP IP Control 1 x 9 pin RS 232 port 1 x 3 5mm IR...

Page 7: ...l Free 877 650 5252 International 1 818 654 5252 Temperature Operating 32 122 F 0 50 C Humidity 20 90 non condensing Dimensions 1RU Rack Mountable Weight 3 Pounds Certifications Compliance FCC HDBaseT CE RoHS HDCP HDMI ...

Page 8: ...8 ZIG SW42 USER MANUAL ...

Page 9: ...to 4K 60 4 2 0 8 bit Advanced EDID management is available through a combination of the 4 pin dipswitch and WebOS 15 EDID tables are available plus you can load custom EDID tables Or leave the SW42 in the default mode and it will pull the EDID from the connected selected display By being able to manage the EDID and HPD Hot Plug Detection you can speed up switching in mixed format systems Control t...

Page 10: ...ID is selected using the WebOS WebOS has 15 EDID tables to select from more to come for various use cases see screen shot below Additionally via the WebOS and custom EDID table can be loaded into the device This gives maximum flexibility as customers can load any EDID they want for the desired application Screen Shot EDID Tables in WebOS Note While DIP 1 is ON DOWN DIPs 2 and 3 are not used DIP 4 ...

Page 11: ... ON HPD is forced active In this mode the SW42 does not process HPD events from downstream to upstream from the sink back to the source This speeds up the HDMI pipeline and can be very useful to avoid a looping condition when multiple HDMI devices are connected in series ...

Page 12: ...12 ZIG SW42 USER MANUAL ZIG SW42 Remote Control SW42 remote control can be used for switching between inputs and powering the SW42 up or down ...

Page 13: ...zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ...

Page 14: ...l number Example for PC http sw42 0001 for Mac http sw42 0001 local You should change it if you are using more than 1 device Change Name below to whatever you want ex CR100SW for conference room number 100 switcher Notes free form field for entering installer notes Video Input Use to select the input you want showing on the display EDID Management ...

Page 15: ...rmware revision Hardware for internal use IP Address IP address of the unit assigned by your DHCP Server Hostname this is what you want to call the unit syntax example CR100RX_k123 This is also the name you type into your browser to access the WebOS Don t us spaces or special characters Factory Reset will erase user entered date like installer notes Choose File Upload Firmware when necessary this ...

Page 16: ...d of response Default RS232 Protocol Settings can be changed in WebOS if required Baud Rate 115200 Data Bits 8 Parity None Stop Bit 1 Flow control None IP DA14 XXXX sp parameter sp parameter sp end of response Commands shown in RS 232 format Help SW42 XXXX help Shows a list of available commands Disco SW42 XXXX disco Uptime SW42 XXXX uptime Shows day hours minutes and seconds the SW42 has been run...

Page 17: ...ware release firware revision build date and serial number Get Device Status SW42 XXXX st Shows active and inactive ports ex Port 1 active port 2 off etc HDMI Input Selection SW42 XXXX insel 1 2 3 4 Lets you change the input Power SW42 XXXX on or off Powers device on or off Ports remain active no picture or sound ...

Page 18: ...s that are made by other manufacturers notably computer hard drives and liquid crystal display panels are limited to the term of the warranty offered by the respective manufacturers Such specific warranties are available upon request to ZIGEN ZIGEN makes no other representation of warranty as to fitness for the purpose or merchantability or otherwise in respect of any of the products sold The liab...

Reviews: