background image

INSTALLATION GUIDE

A10 Thunder Series 930 ADC

26 January 2015

Summary of Contents for Thunder series 930

Page 1: ...INSTALLATION GUIDE A10 Thunder Series 930 ADC 26 January 2015...

Page 2: ...ft ware as confidential information Anyone who uses the Software does so only in compliance with the terms of the End User License Agreement EULA provided later in this document or available separatel...

Page 3: ...emoving a Power Supply 20 Inserting a Power Supply 20 Initial Configuration 21 Management Interface Configuration 21 Connection via Console Serial Port 22 Login via CLI 22 Configure the Management Int...

Page 4: ...ackets 32 Install the Inner Rails 33 Remove the Inner Rails 33 Attach the Inner Rails to the Chassis 33 Attach the Outer Rails to the Rack Posts 34 Install the Chassis on the Rails 36 Power Supply Pro...

Page 5: ...hassis and placing it in the rails is a two person job If needed use an appropriate lifting device Chassis Installation Installation must be performed only by a trained electrician or by a person who...

Page 6: ...ripe and be terminated with a UL listed single hole compression lug The compression lug should be torqued to 15 ft lbs during installation using a Nut and an External tooth washer to ensure the connec...

Page 7: ...ut can operate normally on any DC input from 57 5 to 40 VDC Use at least a 20 amp fuse for each DC breaker Preparing the Site Observe the following The device is designed for use in Network Telecommun...

Page 8: ...A10 Thunder Series 930 Installation Guide Document No TH 930 001 1 26 2015 page 8...

Page 9: ...before inspection by the shipper will void any potential shipping claims CAUTION Do not attempt to install or operate damaged equipment As with any electrical equip ment personal injury or damage to o...

Page 10: ...User Manuals Release Notes and so on Other Requirements Other equipment needed for installation Notebook or workstation PC Windows Linux Mac Must have compatible Ethernet connectivity Supported Web br...

Page 11: ...he data interfaces you plan to use 3 Optionally connect an Ethernet cable to the MGMT interface LED Locations and Status Indicators The figures in this section provide close up views of the interfaces...

Page 12: ...System under access Off No power access DISK Amber On SSD under access Off No Data access 10 Gb Ethernet Ports Fiber LNK Green Off Link down On Link up ACT Green Off Port is not sending or receiving...

Page 13: ...l shutdown use the shutdown command in the CLI If you made any changes to the device configuration you will be prompted to save your configuration information before the device powers down Force Power...

Page 14: ...A10 Thunder Series 930 Installation Guide Power On Document No TH 930 001 1 26 2015 page 14...

Page 15: ...wer cable which enables quick and easy installation of the power supplies without the need to disturb the AC or DC terminal blocks AC or DC power is connected to each module sep arately Before extract...

Page 16: ...A10 Thunder Series 930 Installation Guide Overview Document No TH 930 001 1 26 2015 page 16 FIGURE 4 Example of AC Power Supply FIGURE 5 Example of DC Power Supply...

Page 17: ...serted DC Power Supply Installation Refer to the following instructions and figures for this procedure Also see figures on previous page NOTE Use at least a 20 amp fuse for each DC breaker 1 Attach Gr...

Page 18: ...A10 Thunder Series 930 Installation Guide DC Power Supply Installation Document No TH 930 001 1 26 2015 page 18 FIGURE 7 Connecting the DC Power Supply Cable...

Page 19: ...5 A10 Thunder Series 930 Installation Guide Power Supply Hot Swap FIGURE 8 DC Power Supply Cables Power Supply Hot Swap Follow the directions in the following sections to remove and insert a power sup...

Page 20: ...015 page 20 Removing a Power Supply To remove a power supply 1 Push and hold the panel to unlock the lock A 2 Hold the panel and pull out the power supply Inserting a Power Supply To insert a power su...

Page 21: ...ura tion on page 24 Management Interface Configuration This section describes how to perform initial configuration on your ACOS device using the CLI which is accessed using a console connection The fo...

Page 22: ...g the Enter key There is no default password to enter Privileged EXEC mode on new systems ACOS en Password just press Enter on a new system ACOS Enable the configuration mode by typing config and pres...

Page 23: ...ask is 255 255 255 0 5 Optionally configure the ACOS device to use the management interface as the source interface for automated man agement traffic generated by the ACOS device ACOS config if manage...

Page 24: ...be repeated Saving the configuration changes prevents this inconvenience To write the current configuration to system memory ACOS config write mem Building configuration OK Configuring a New ACOS Devi...

Page 25: ...dule Inserting a Fan Module Fan Module Location and Fan Numbers The location of the fans is shown in Figure 10 When facing the back panel the fans are numbered 1 4 from left to right FIGURE 10 Fan Mod...

Page 26: ...26 FIGURE 11 Removing a Fan Module Inserting a Fan Module Follow the steps below in order to remove a fan module 1 Gently push the fan module into the slot 2 Tighten both screws to secure the fan mod...

Page 27: ...vices are shipped with screws on the side of the chassis to be used in conjunction with the new screwless sliding rail kit A10 Thunder Series 5330 S A10 Thunder Series 3430 S A10 Thunder Series 3230 S...

Page 28: ...head screws that will be used to attach the bracket to the chassis Make sure to use the correct bracket Each bracket fits on only one of the chassis sides 2 Remove the screws 3 Align the bracket over...

Page 29: ...screws that will be used to attach the bracket to the chassis Make sure to use the correct bracket Each bracket fits on only one of the chassis sides 2 Remove the screws 3 Align the bracket over the s...

Page 30: ...A10 Thunder Series 930 Installation Guide Center Mount Installation Document No TH 930 001 1 26 2015 page 30...

Page 31: ...e verify that all parts are included and are not damaged 2 x adjustable rail assemblies 12 x black 4 mm flat head screws for attaching the inner rails to the chassis 13 x silver M5 thread 7 mm flat he...

Page 32: ...ese brackets are intended to prevent the device from sliding out in the event of an earthquake or excessive vibration 1 Attach the mounting brackets to the sides of the chassis using the small silver...

Page 33: ...s lock into place 2 Release the inner rail by pressing the finger tab located near the middle rail in the direction of the arrow NOTE The outer and middle rails cannot be separated Attach the Inner Ra...

Page 34: ...t No TH 930 001 1 26 2015 page 34 3 Repeat for the other inner rail Attach the Outer Rails to the Rack Posts To attach the outer rails to the rack posts 1 Align the top and bottom screw holes at the f...

Page 35: ...e rail kit NOTE If you plan to use your own screws please make sure they are not too long to fit into the rail NOTE Do not completely tighten the screws yet They need to be loose so you can adjust the...

Page 36: ...o priate lifting device 1 Standing in front of the rack fully extend the inner rails until the extension locks engage if not already engaged When the extension locks are engaged the rails cannot be pu...

Page 37: ...4 Press the finger tab located near the front of the chassis You can push the tab in either direction This unlocks the rails so you can slide the chassis into the rack 5 Carefully slide the chassis a...

Page 38: ...A10 Thunder Series 930 Installation Guide Sliding Rail Kit Installation Document No TH 930 001 1 26 2015 page 38...

Page 39: ...w active LED indicators Green Output LED On when the AC outputs are within the valid range and stable AC Input Voltage Range 90 VAC 264 VAC AC Input Current Nominal input voltage Min 100 VAC Nom 230 V...

Page 40: ...ED On when the AC outputs are within the valid range and stable DC Input Voltage Range 40 VDC 72 VDC Use at least a 20 amp fuse for each DC breaker DC Input Current Nominal input voltage Nom 53 VDC Ma...

Page 41: ...o are available on the A10 Networks support site For feature information see the following guides Basic Setup System Configuration and Administration Guide Security Guides Application Access Managemen...

Page 42: ...essful resolution contact customer support using the information in this section They will be able to assist you with return authorization and instructions A10 Networks Inc 3 W Plumeria Dr San Jose CA...

Page 43: ...page 43 Document No TH 930 001 1 26 2015 A10 Thunder Series 930 Installation Guide...

Page 44: ...Document No TH 930 001 1 26 2015 4...

Reviews: