manualshive.com logo in svg
background image

 

 

QuantaMesh 

T1048-LB9M 

 

Network Switch 

Installation Guide 

Содержание QuantaMesh T1048-LB9M

Страница 1: ...QuantaMesh T1048 LB9M Network Switch Installation Guide...

Страница 2: ......

Страница 3: ...nology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments such a...

Страница 4: ...ly be serviced by trained service technician If any of the following conditions occur unplug the equipment from the electrical outlet and replace the part or contact a trained service technician The p...

Страница 5: ...ion cable with properly grounded plugs Observe extension cable and power strip ratings Ensure that the total ampere rating of all products plugged into the extension cable or power strip does not exce...

Страница 6: ...ack kit The rail racks are designed to carry only the weight of the system Do not place additional load onto any rail mounted equipment System rack kits are intended to be installed in a rack by train...

Страница 7: ...e power cord to the power supply being replaced before removing it from the switch Power Cord Warnings If an AC power cord was not provided with your product purchase one that is approved for use in y...

Страница 8: ...the system without the fan guard in place Rack Mount Warnings The following installation guidelines are required by UL for maintaining safety compliance when installing your switch into a rack The equ...

Страница 9: ...otherwise damage a battery Cooling and Airflow CAUTION Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with...

Страница 10: ...expressly approved by the grantee of this device could void the user s authority to operate the equipment The customer is responsible for ensuring the compliance of the modified product Only periphera...

Страница 11: ...and TUV and VDE licensed Maximum power rating of any one device is 19 watts Total server configuration is not to exceed the maximum loading conditions of the power supply Restriction of Hazardous Sub...

Страница 12: ...mplies with Part 15 of the FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference...

Страница 13: ...n 19 Hardware Installation 20 Unpacking the Hardware 20 Package Contents 20 Installing the Switch 20 Site Survey 20 Positioning the Switch 21 Rack Mounting the Switch 21 Connecting to the Console Port...

Страница 14: ...a center as the rack management switch With QNOS supported QuantaMesh T1048 LB9M offers the complete layer2 layer3 functions which are right fit for contemporary data center Chassis for the T1048 LB9M...

Страница 15: ...QuantaMesh T1000 Series 13 Network Switch Installation Guide Rear panel No Item No Item 1 PSU LEDs 4 Fan LEDs 2 PSU2 5 Fixed Fan Modules 3 AC Power Connector with Plug Retainer 6 PSU1...

Страница 16: ...itch is loading the agent software code FAN LED front panel bi color green red LED number One per system on the front panel Off None Red Solid Any one of fans is not operating well Red Blinking None G...

Страница 17: ...ne RJ45 GE Port Link Activity LED bi color green amber LED number One per port on the right each port Off No link Amber Solid None Amber Blinking None Green Solid The port is linked Green Blinking The...

Страница 18: ...t attached cable For more information on obtaining the appropriate SFP28 modules refer to Supported Cables and Transceivers The management port enables you to manage the switch operation using an RJ 4...

Страница 19: ...of T1048 L SFP28 Port Connection The switch is equipped with 4 SFP28 ports designed for 25Gbps data rate The SFP28 ports support 25 Gigabit Ethernet following IEEE 802 3ae Ethernet for fiber mediums T...

Страница 20: ...direction label on the rear panel to determine its airflow direction Red indicates front to back airflow Blue indicates back to front airflow The AC power connector is a standard three pronged connec...

Страница 21: ...t to Back Airflow The air intake is located on the front panel of the switch The cool air is sucked in from outside the chassis and pushed toward the rear of the chassis The hot air exhausts through t...

Страница 22: ...flat and stable surface and cut the straps securing the box 2 Carefully remove the switch Then place it on a flat and clean surface 3 Remove all other items from the box and inspect each item Install...

Страница 23: ...l on the rear panel to determine its airflow direction Red indicates front to back airflow air inlet module See Front to Back Airflow Blue indicates back to front airflow air outlet module See Back to...

Страница 24: ...ward to release the inner rail from the middle rail Remove the inner rail NOTE Repeat the similar steps to remove another inner rail 2 Pull the tab upward to unlock the latch and then push the middle...

Страница 25: ...les on the rail mounting brackets with the switch 7 Secure the rail mounting brackets with screws 8 Align the hooks on the switch with the holes in the inner rail and then slide the inner rail backwar...

Страница 26: ...install the rear bracket Align and push the rail firmly into the rear rack until it clicks into place Make sure the L shaped bracket is facing inward 11 Pull the middle rail out until it is fully exte...

Страница 27: ...on Below is the console cable wiring specification table RJ 45 Port of Switch DB9M Female Port of PC Abbreviation Description 3 2 RD Received Data 6 3 TD Transmit Data 1 8 CTS Clear To Send 8 7 RTS Re...

Страница 28: ...and data rate can be in 10Mbps 100Mbps or 1Gbps Telnet SNMP and Web browser utility can all go through this port for local or remote management after the IP address subnet mask and default gateway ar...

Страница 29: ...a time Two circuits provide redundancy protection NOTE Each PSU has an AC power connector At least one power supply must connect to a power source Connecting the Power Source To connect the switch to...

Страница 30: ...rt module PSU PSU1 PSU2 LED is in Red state Possible issues Fan Lock 15 sec OTP Over Temperature Process OCP Over Current Process OVP Over Voltage Process UVP Under Voltage Process Fan LED is in Red s...

Страница 31: ...pply will cause the switch to automatically shut down The PSU s can be replaced without the use of special tools Before replacing any of the PSUs verify the status of the PSU to determine if there is...

Страница 32: ...e are no user serviceable parts inside the PSU Do not disassemble any part of the PSU Doing so voids the warranty and regulatory certifications For maintenance services not mentioned in this guide ple...

Страница 33: ...of different protocols i e FTP TFTP and HTTP to download the installer file from your local server To download and update the vendor OS code manually perform the following 1 Locate the specific QUANT...

Страница 34: ...t 4 In ONIE Linux shell use the install_url command to update the vendor OS code Use one of the following commands install_url tftp 192 168 2 153 ly3 onie installer 1 5 3 or install_url ftp 192 168 2...

Отзывы: