Important Information 

 

 

DANGER! 
 Hazardous voltage! 
 Will cause death or serious injury. Turn off and lock out all power 
 supplying this device before working on this device. 

 

To use the equipment flawless and safe, transport and store properly, install and start professionally and 
operate as directed. 
Only let persons work with the equipment who are familiar with installation, start and use and who have 
appropriate qualification corresponding to their function. They must observe the contents of the instructions 
manual, the information which are written on the equipment and the relevant security instructions for the 
setting up and the use of electrical units. 
The equipment  is built according to  DIN / EN and checked and leave the plant according to security in 
perfect condition. If, in any case the information in the instructions manual is not sufficient, please contact 
our company or the responsible representative. 
To  maintain  this  condition,  you  must  observe  the  safety  instructions  in  this  instruction  manual  titled 
“Important  Information”.  Failure  to  follow  the  safety  instructions  may  result  in  death,  personal  injury,  or 
property damage to the equipment itself and other equipment and facilities. 
Instead of the industrial norms and regulations written in this instruction manual valid for Europe, you must 
observe out of their geographical scope the valid and relevant regulations of the corresponding country. 

Installation 

The unit can be installed as follows: 

  Installation in switchgear cabinet on 35 mm mounting rail according to EN 60715 for protection against 

fire, external environmental conditions and mechanical effects. 

  With screws M4 for installation on walls or panel. (additional latch is not included in delivery) 

  Connection according to connection plan or type plate. 

 
Failure to comply with the information in this instruction manual will not guarantee the function of the device. 
 

A circuit-breaker or switch must be situated within easy reach of the  
unit and fused. Insta

llation excess current protection should be ≤ 10 A. 

 

 

 

Attention! Universal power supply

 

The device have a universal power supply, that is suitable for DC- and AC-voltages. 
Before connecting the device to supply-voltage make sure that the connected voltage 
corresponds with the voltage on the lateral type on the device 

 

Observe  the  maximum  temperature  permissible  when  installing  in  switching  cabinet.  Make  sure 
sufficient  space  to  other  equipment  or  heat  sources.  If  the  cooling  becomes  more  difficult  e.g. 
through close proximity of apparatus with elevated surface temperature or hindrance of the cooling 
air, the tolerable environmental temperature is diminishing. 

 
 

 

Summary of Contents for MU1000K

Page 1: ...e www ziehl de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching Relays and Controls Measuring Transducers Grid and Plant Protection Operating Manual MU1000K updated 2018 11 12 sm from Firmware 0 04 MU1000K 12370 0705 01 Page 1 12 www ziehl de Universal Measuring Transducer ...

Page 2: ...mmissioning 5 6 1 Overview of commissioning 5 6 2 Overview of the predefined standard ranges 5 6 3 Setting a predefined range 6 6 4 Diagram for setting a predefined range 7 6 5 Query firmware version on the device 8 6 6 Overview of scaling an arbitrary range 8 6 7 Scaling of range 8 6 8 Diagram for scaling of range 9 6 9 Factory setting 10 7 Error search 10 8 Technical data 10 9 Housing Type K 12 ...

Page 3: ... mA are potentially separated from inputs and supply voltage With its universal power supply AC DC 24 240 V the measuring transducer can be connected to all common supply voltages 2 Overview of functions Current input 0 20mA scalable Voltage input 0 10V scalable Input Pt 100 3 wire 200 800 C scalable Output signal 0 20mA and 0 10V or 4 20mA and 2 10V Rated Supply Voltage AC DC 24 240V Insulation b...

Page 4: ... Instead of the industrial norms and regulations written in this instruction manual valid for Europe you must observe out of their geographical scope the valid and relevant regulations of the corresponding country 5 Installation The unit can be installed as follows Installation in switchgear cabinet on 35 mm mounting rail according to EN 60715 for protection against fire external environmental con...

Page 5: ...1000K setting a predefined range Point 6 5 6 7 MU1000K scaling an arbitrary range 6 2 Overview of the predefined standard ranges Following standard ranges can be set without adjustment to the unit Input U I Input Pt 100 Output Zero point Full scale Zero point Full scale Zero point Full scale 0 V 10 V 200 C 0 V 10 V 2 V 10 V 50 C 2 V 10 V 0 mA 20 mA 0 C 0 mA 20 mA 4 mA 20 mA 100 C 4 mA 20 mA 200 C ...

Page 6: ...the zero point of the input Number of LED flashes Pt100 U I 1 x 200 C 0 V 0 mA 2 x 50 C 2 V 4 mA 3 x 0 C 4 x 100 C 5 x 200 C Press button Down Parameterization input full scale only for Pt100 input LED Power flashes 3x Select with button Set the full scale of the input Number of LED Number of LED flashes Pt100 flashes Pt100 1 x 0 C 5 x 200 C 2 x 50 C 6 x 250 C 3 x 100 C 7 x 300 C 4 x 150 C 8 x 400...

Page 7: ...MU1000K 12370 0705 01 Page 7 12 www ziehl de 6 4 Diagram for setting a predefined range Mode Normal state Parameterization mode ...

Page 8: ... the device and keep pressed the button Down After 5s flashes the green LED release button Down Parameterization input type LED Power flashes 1x Select with button Set the input type displayed by LEDs Pt100 U I Press button Down Parameterization input zero point LED Power flashes 2x Connect a signal at the input corresponding to the zero point Press button Down store of value green LED flashes 3 t...

Page 9: ...MU1000K 12370 0705 01 Page 9 12 www ziehl de 6 8 Diagram for scaling of range Signal input Zero point Signal input Full scale Mode Normal state Parameterization mode ...

Page 10: ...sumption 3 W 5 VA Inputs Input resistance Maximus Input signal Error of full scale Voltage input 12 kΩ DC 27 V 0 1 Current input 18 Ω DC 100 mA 0 5 Resolution 14 Bit Measuring range Max Resistance of sensor wire Pt100 sensor input 200 C 800 C 500 Ω Tolerance 0 5 of measured value 0 5 K Resolution 0 1 C Sensor current 0 6 mA Temperature factor 0 04 C K Outputs 2 outputs with common ground Voltage o...

Page 11: ...issible ambient temperature 20 C 65 C Permissible storage temperature 20 C 70 C Permissible wiring temperature 5 C 70 C Climatic conditions 5 85 rel humidity no condition Installation height 2000 m over N N Vibration resistance EN 60068 2 6 2 25 Hz 1 6 mm 25 150 Hz 5 g Auxiliary supply 18V 20mA Supply voltage for external measuring transducer DC 15 20V 25mA Housing Type K Dimension H x W x D 75 x ...