MU1000K
12370-0705-01
Page
3 / 12
www.ziehl.de
1
Application and short description
Universal-measuring-transducers MU1000K can measure signals Pt100 (RTD) and DC current (0/4-20 mA)
and voltage (DC 0/2-10 V). Several measuring-ranges are pre-programmed. More can be easily scaled.
Temperatures at sensors Pt 100 can be evaluated from -200 °C to + 800 °. The output-signals 0/2-10 V and
0/4-20 mA are potentially separated from inputs and supply voltage. With its universal power-supply AC/DC
24-240 V the measuring transducer can be connected to all common supply-voltages.
2
Overview of functions
•
Current input 0-20mA, scalable
•
Voltage input 0-10V, scalable
•
Input Pt 100, 3-wire, -
200…+800 °C, scalable
•
Output signal 0-20mA and 0-10V or 4-20mA and 2-10V
•
Rated Supply Voltage AC/DC 24-240V
•
Insulation between inputs, outputs and supply voltage
•
Standard ranges adjustable, universally scalable input ranges
3
Connecting diagram
For Pt100 2-wire connection: Bridge from terminal 6-7.