background image

WWW.ARTEL.COM

MANUAL

16 or 32 channels of audio over one  
single mode or multimode fiber.

Installation and Operations  
Manual

FiberLink 

4160 and 4320 Series

Summary of Contents for FiberLink 4160 Series

Page 1: ...WWW ARTEL COM MANUAL 16 or 32 channels of audio over one single mode or multimode fiber Installation and Operations Manual FiberLink 4160 and 4320 Series ...

Page 2: ...ckage Contents 3 Technical Specifications Model Part Number Specifications 4 General Specifications 4 Installation Instructions 6 Audio Switch Settings Options 7 System Terminal Block Connections 8 Indicator LEDs 9 Operating Pointers 10 Troubleshooting 10 Maintenance and Repairs 11 Certifications 11 Contents ...

Page 3: ...nit to continuously signify the presence of audio signals and thus the proper operation of each side of the system Features TransmitTransmits over one multimode or single mode fiber at 850 1310 or 1550 nm Optional redundant optical input output System consists of transmitter and receiver unit No adjustments pure digital processing and transmission 24 bit 96 kHz sampling maximum audio level 24 dBu ...

Page 4: ...onnector S ST Connector zz NA North Amercian Line Cord EU European Line Cord JP Japan Line Cord UK Unitd Kingdom Line Cord AU Australia Line Cord General Specifications LED Indicators Power Audio Present per channel Alarm LED card version only Power Requirements 95 250 volts AC 47 63 Hz Operating Temperature Range 35o to 55o C Relative Humidity 10 90 non condensing Optical Connectors ST or FCPC Op...

Page 5: ...f fiber Crosstalk Min 95 dB 1 kHz Input Impedance 600 Ohms terminated 24 k Ohms unterminated Output Impedance 50 Ohms Audio Connectors Removable screw terminal Switches Dip switches to select input termination balanced or unbalanced input output Selectable on a per channel basis Operating Loss Budget Maximim Useable Distance 850nm Multimode 0 20 dB 0 2 km 1310nm Multimode 0 25 dB 0 10 km 1310nm Si...

Page 6: ... is desired please refer to instructions on page 7 2 Connect the fiber optic cable between the two Fiberlink units 3 Apply power to both units 4 When power is applied the green POWER LED will light indicating the presence of operating power 5 Connect the audio input signals to the proper positions on the removable terminal blocks See Page 8 Be certain to check all connections and assure that input...

Page 7: ...nel 12 may be configured to have balanced input on the transmitter unit and unbalanced output on the receiver unit The chart below indicates how to use the BAL UNBAL set of switches One switch corre sponds to each channel available in the series High Impedance 24k Ohm Termination The transmitter unit has a second set of switches that allows the user to select between a high impedance 24 k Ohm inpu...

Page 8: ...sition 3 Position 3 Position G Position 4 Position 4 Audio Connector Receiver Position Balanced Unbalanced Position 1 Channel 1 Output Channel 1 Ground Postition 1 Channel 1 Output Channel 1 Signal Position G Ground Position 2 Channel 2 Output Channel 2 Ground Position 2 Channel 2 Output Channel 2 Signal This pattern continues for all available channels in the series Odd and even positions are gro...

Page 9: ... audio input detected Receiver LEDs LED Status Definition Power On Indicates that correct power has been applied Audio Off Indicates no audio detected on the fiber 1 16 or 1 32 Blinking Indicates audio detected on the fiber Optic 1 2 Off Indicates normal operation On Indicates no signal on fiber or fiber not connected Indicator LEDs The FiberLink 4160 4320 Series has indicator LEDs that are used t...

Page 10: ...al failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal connections are correct An optical power meter such as the FiberLink 6650 a visible light source such as the FiberLink 6656 and a Three Wavelength Light Source such as the FiberLink 6652 can greatly assist and expedite troubleshooting of fiber optic tra...

Page 11: ...with light transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the FiberLink 6650 a visible light source such as the FiberLink 6656 and a Three Wavelength Light Source such as the FiberLink 6652 can greatly assist and expedite troubleshooting of fiber optic transmission ...

Page 12: ...ctured in the USA Training and installation support available 24x7x365 technical support available Proven Products Unrivaled Service and Great Support Artel Video Systems Corp 5B Lyberty Way Westford MA 01886 USA T 978 263 5775 F 978 263 9755 sales artel com customercare artel com www artel com All specifications subject to change without notice 2016 Updated 02 16 2016 CS200 122915 00_J ...