Parameter
Function
Explanation
35:HY_DOWN
Direction DOWN at hydraulic elevator
with Bucher aggregate type Saturn
ALPHA and Orion ALPHA
The input functions RF+RV2+V1 are activated simultaneously
when the input is activated
only in ZAdyn HY
36:/FastStp
Delay in emergency stop
When deactivating the input the motor is braked with the delay
set in the "Controller/A_MAX" menu
37:DTE
Ziehl-Abegg test function
Reserved for Ziehl-Abegg
38:RECORD
Recorder function
Start or stop measurement by external signal
Input activated:
Measurement is active
Input deactivated:
Measurement is stopped and saved
39:INV_A1
Direction UP at hydraulic elevator with
Bucher aggregate type Orion ALPHA
Inverting the analog target value A1
40:FKT.ana
Ziehl-Abegg test function
Reserved for Ziehl-Abegg
41:Monitor
Monitoring function for manually evac-
uation
Shown evacuation direction and evacution speed
42: LZ
Distance-dependent deceleration after
standstill
With active input there is a deceleration after speed 0, even
when travel speeds are activated.
The deceleration from travel speed V1 depends on the distance
programmed for the parameter S_10.
43:STANDBY 1
Standby 1
Switching the ZAdyn4C to Standby 1 function to save energy
44: ZR_RDY
ZArec ready
ZArec monitoring function
45: /ESC
/ESC
Electronic short-circuit is deactivated
46:SBC_RDY
ZAsbc4C ready
ZAsbc4C monitoring function
47:CO
Function not assigned
48: EVA act.
Display: Battery evacuation active
If switching to battery supply takes place during travel, this input
function must be set.
49: MOT_TEMP
External motor temperature monitoring
If an external device is used for monitoring the motor temper-
ature, this input function can be used to display overtemperature
of the motor.
Parameter descriptions for digital outputs
Parameter
Function
Explanation
Off
Output has no function
Output is open all the time
RB
Controller ready
Switching the motor contactors
Activating the inputs of the STO func-
tion
Contact closes when the following signals are present: Control-
ler enable, travelling speed and direction speci
fi
cation. When
closing the contact, the inputs of the STO function must be
activated without delay or the motor contactors connected.
/RB
Inverted function of "RB contactor"
Contact opens when the following signals are applied: Controller
enable, traveling speed and direction default.
V<V_G1
Speed monitoring
Contact opens when the limit value V_G1 set in the
“
Control
”
menu is exceeded.
V<V_G2
Speed monitoring
Contact opens when the tolerance set in the "Control system"
menu V_G2 is exceeded.
V<1.1*V_3
Speed monitoring
Contact opens when the traveling speed V3 is exceeded by
10%.
Warning
Warning
Monitoring of the motor temperature (for ZAdyn4) and the tem-
perature of the power section.
Contact opens if a malfunction advance warning is present
because of an excess temperatur. The current trip will be trav-
eled to the end. The advance warning can be evaluated by the
open loop control and a new start can be prevented.
Fault
Fault
Contact is closed if no error is present in the ZAdyn4C.
Evac.Dir.
Evacuation direction
Contact open: Car is lighter than counterweight
Contact closed: car is heavier than counterweight
Original operating instructions
ZAdyn4C
Parameter list