Parameter
Designation
Value range
Factory set-
ting
BR
Motor brake monitoring
Input of number and function of the brake monitoring contacts
used
OFF:
No brake monitoring connected
1*NC:
1x normally closed contact (Contact closed when brake
currentless)
2x NC:
2x Normally closed contact (contact closed when brake
is currentless)
3x NC:
3x Normally closed contact (contact closed when brake
is currentless)
1*NO:
1 x normally open (contact is open when brake current-
less)
2x NO:
2x Normally open contact (contact open when brake is
currentless)
3x NO:
3x Normally open contact (contact open when brake is
currentless)
4*NC:
4 x normally closed contact (Contact closed when brake
currentless)
4*NO:
4 x normally open (contact is open when brake current-
less)
Off
1*NC
2*NC
3*NC
1*NO
2*NO
3*NO
4*NC
4*NO
accordingly to
motor type
P1P2
Motor temperature monitoring
OFF:
Temperature monitoring deactivated
PTC:
thermistor (PTC according to DIN 44082)
TC:
Thermal circuit breaker
KTY:
Temperature sensor KTY84-130
Off
PTC
TC
KTY
PTC
K_START
Start gain
Multiplication factor for the parameter "control/SPD_KP" or am-
pli
fi
cation of the position controller (dependent on the start-up
mode)
is automatically
limited
1.0
SPD_KP
Multiplication factor to modify the calculated basic ampli
fi
cation
SPD_C
is automatically
limited
1.0
12.2
Advanced-Level
The menus of the advanced level are described below. See the chapter "Operation and Parameter-
isation / The different operating levels" for information about the advanced level.
12.2.1
LCD & Password menu
Selection the desired operating language. Protects the ZAdyn4C from access by third parties by
assigning a password.Modifying the parameters is only possible after entering the password. A pass-
word is not factory set.
Parameter
Designation
Value range
Factory set-
ting
LANG
Select the desired operating language.
The operating languages German and English are integrated
into the device as standard.
A third operating language can be loaded with the memory card.
To do this, the language
fi
les must be stored on the memory
card in the following folder: 4CX\Update\O_TEXT
Deutsch
English
T
ü
rkce
Nederland
Espanol
Italiano
Svenska
Czech
France
Polski
Po Russki
Deutsch
Original operating instructions
ZAdyn4C
Parameter list
R-TBA12_01-GB 2104 Index 012
Part.-No. 00163371-GB
87/224
1
2
P
a
ra
m
e
te
r
lis
t