Starting with default acceleration
RF
Controller enable
V_1
Positioning speed
V_3
High travelling speed
RV1 / RV2
Direction default
RB
Controller ready
MB_Brake
Mechanical brake
13.2.2
Acceleration with intermediate speed
It is possible to accelerate to different intermediate speeds when starting.
V
RF
V_1
V_3
V_2
RB
MB
RV1 / RV2
X-IN
X-OUT
t
Starting with acceleration from V_1 to V_2
13.3
Optimizing start up behavior
Optimizing the start up behavior is only necessary if there is a negative in
fl
uence on the travel comfort
(e.g. through start up jerks)
Information
•
Proper installation condition (rail guides, car suspension, transmission oil
fi
lling, etc.)
•
The car must be empty and the counterweight completely loaded. Start-up for all loading conditions
can only be optimally adjusted in under these conditions
•
The speed control parameters must be correctly set in the
Controller
menu (see "Commissioning /
Setting the speed control" chapter)
Original operating instructions
ZAdyn4C
Travel options
R-TBA12_01-GB 2104 Index 012
Part.-No. 00163371-GB
123/224
1
3
T
ra
v
e
l
o
p
ti
o
n
s