9.6.2
Curve for Setpoint compartment temperature
Setpoint curve
Setpoint curve
Factory setting setpoint curve active = ON, if curve program is switched
on.
This curve can be deactivated = OFF if necessary
Setpoint start
Setpoint start
setting range: 0.0..40.0
°
C
Factory setting: 26.0
°
C
Increase program Setpoint
Day
[°C]
31.10.2008
v_sollw_kurve.VSD
S
0
Start
Knickpunkt1
Break-point1
Knickpunkt2
Break-point2
Endpunkt
Final day
1
2
E
[
°
C] Setpoint in
°
C
SS
etpoint start
1 Setpoint knick1
2 Setpoint knick2
E Setpoint
nal
Setpoint knick1
Setpoint knick1
setting range: 0.0..40.0
°
C
Factory setting: 24.0
°
C
Setpoint knick2
Setpoint knick2
setting range: 0.0..40.0
°
C
Factory setting: 23.0
°
C
Setpoint
nal
Setpoint
nal
setting range: 0.0..40.0
°
C
Factory setting: 20.0
°
C
9.6.3
Curve for Minimum Ventilation
Minimum curve
Minimum curve
Factory setting min. curve active = ON, if curve program is switchedon.
This curve can be deactivated = OFF if necessary
Min. start
Min. start
Setting range: OFF - 6...100
%
Factory setting: 10 %
Increase program Minimum
Day
[%]
31.10.2008
v_min_kurve.VSD
S
0
Start
Knickpunkt1
Break-point
Knickpunkt2
Break-point
Endpunkt
Final day
1
2
E
[%] Minimum Ventilation in %
SMin. start
1 Min. knick1
2 Min. knick2
E Min.
nal
Min. knick1
Min. knick1
Setting range: OFF - 6...100
%
Factory setting: 12 %
Min. knick2
Min. knick2
Setting range: OFF - 6...100
%
Factory setting: 17 %
Min.
nal
Min.
nal
Setting range: OFF - 6...100
%
Factory setting: 25 %
Operating Instructions
UNIcon / Acontrol
Settings for operation
L-BAL-E051-GB 1035 Index 003
Part.-No. 00163311-GB
62/83