![ZIEHL-ABEGG Fcontrol FTET4AHMQ-L Operating Instructions Manual Download Page 8](http://html1.mh-extra.com/html/ziehl-abegg/fcontrol-ftet4ahmq-l/fcontrol-ftet4ahmq-l_operating-instructions-manual_3698482008.webp)
2.9
Employment of external personnel
Maintenance and service work are frequently carried out by external employees who often do not
recognize the speci
fi
c situations and the thus resulting dangers.These persons must be comprehen-
sively informed about the hazards in their area of activity.
You must monitor their working methods in order to intervene in good time if necessary.
3
Product overview
3.1
Operational area
The frequency inverter is designed for a stepless control of fans without additional (electromagnetic)
motor noise.
Temperature controller for stalls in individual or central exhaust air systems.
•
In
installations with single suction
, fans,
fl
aps and heatings are controlled via the outputs.
•
In
central exhaust installations
, these devices are used in combination. The devices controls the
exhaust air
fl
ap and the heatings for one ompartment. At the same time the exhaust air volumes of
all the compartments connected are signaled to a
Master*
. The speed is calculated from the sum
of the exhaust air volumes and the fans connected are readjusted.
In order to be able to network several devices, these are equipped with a bus interface. In this way, for
example, the supply air temperature sensor connected to the
Master*
can be communicated to all
system users. Fault messages on stall devices are transmitted and displayed as a group fault; in
addition the total exhaust air volume of the ventilation system is determined.
Master*
A device which controls and monitors the bus communication and performs central control functions
3.2
Service work
The device must be checked for soiling and, if necessary, cleaned in periodic intervals.
3.3
Transport
•
The device is packed ex factory to suit the transport method previously agreed.
•
The device may only be transported in the original packaging.
•
Avoid shocks and impacts to the device during the transport.
•
During manual handling the human lifting and carrying restrictions must be observed and adhered
to.
3.4
Storage
•
The device must be stored in its original packaging in a dry and weather-proof room.
•
Avoid exposure to extreme heat and cold.
•
Avoid prolonged storage; we recommend a maximum of one year (consult the manufacturer before
starting if stored for longer).
3.5
Disposal / recycling
Disposal must be carried out professionally and in an environmentally friendly way in accordance with
the respective national legal stipulations.
"
Separate the materials by type and in an environmentally-friendly way.
"
If necessary, commission a specialist company with the waste disposal.
Operating Instructions
Fcontrol
–
model series FTET4/6/10AHMQ-L
Product overview
L-BAL-E139-GB 2022/03 Index 006
Part.-No.