MAINTENANCE AND USE MANUAL

elite mix

EN

CHAPTER 9:   TROUBLESHOOTING

9.1

WARNING

9.2

PROBLEMS, CAUSES AND REMEDIES

Should any of the anomalies described below occur try setting the situation 

right, as far as is permissible, by following the instructions contained in this 

manual. Should the problem persist contact your Authorised Servicing Centre.

 

p

roblem

 

C

ause

 

r

emeDy

It is difficult to 

create a 

vacuum in the 

containers.

1.

  The  gaskets  between  the 

various components are dirty, 

damaged or positioned 

incorrectly.

2.

 Faulty pump.

3.

 Intake filter clogged.

1. 

Examine  the  gaskets,  clean  if 

necessary  and  lubricate  them  with 

Vaseline.  Clean  mixing  unit  components 

thoroughly (see paragraph 8.1.1).

2.

 Contact an Authorised Service Centre.

3.

 Change the filter (see section 8.1.2).

After turning the 

main  switch  to 

ON the machine 

does  not  work.

1.

 Plug is not connected to 

the mains socket.

Power lead is damaged.

2.

 Fuse blown.

1.

 Connect the plug to the mains socket 

properly.

2.

 Change the fuse, using one of identical 

characteristics. Contact an Authorised 

Servicing Centre only.

The pump does 

not start.

1.

 Sensor on board and/or 

magnet on cup lid faulty.

1.

 Contact an Authorised Service Centre.

Error n°1: 

if, 2 minutes after positioning the cup, the pressure still hasn’t dropped below the 

threshold (= 50) a warning appears and the pump is switched off. In this case it is necessary to 

carry out an inspection and trace the problem (e.g. the cup may be positioned incorrectly, the 

vacuum sensor tube disconnected, the pump disconnected…) before restarting the cycle.

Error n°2:

  if,  during  the  cycle,  the  cup  is  no  longer  detected,  a  warning  appears  and  the 

outputs are deactivated. In this case it is necessary to carry out an inspection and trace the 

problem and then restart the cycle. This error may occur if the vacuum sensor is faulty: 

measured pressure may be below the threshold (otherwise error 3 would be shown) but the cup 

detaches. In this case the motor is stopped to prevent injury to the operator.

Error n°3: 

if, during the cycle, the vacuum is insufficient (i.e. pressure rises above the 

threshold = 50) a warning appears and the motor is switched off. this case it is necessary to 

carry out an inspection and trace the problem (e.g. cup detached, vacuum sensor tube 

disconnected, pump disconnected…) before restarting the cycle.

Error n°4:

 when the 

elite mix

 control unit is switched on the pump is activated for 5 seconds to 

check whether the filter is dirty (i.e. without the cup): if the pressure drops below a certain level this 

means  that  the  filter  is  clogged  and  an  error  warning  appears.  In  this  case  the  filter  must  be

replaced.

9.3

ERROR WARNINGS

Summary of Contents for elite mix

Page 1: ...User Manual Vacuum mixers IT FR ES HR RU ZH DE EN elite mix...

Page 2: ......

Page 3: ...l characteristics and operating start Pag 111 4 2 Technical Data Pag 111 4 2 1 Weight and overall dimensions Pag 111 4 2 2 Standard accessories Pag 111 4 2 3 Accessories available on request CH 5 TRAN...

Page 4: ...g 129 A 1 CE Declaration of conformity Pag 130 A 2 Warranty certificate and identification form Pag 131 A 3 Maintenance and repair worksheet Pag 132 A 4 Authorized service partners Pag 132 A 5 Notes T...

Page 5: ...away from sunlight atmospheric agents etc It must be available for consultation throughout the working life of the machine even when the machine is sold or finally dismantled It is recommended that y...

Page 6: ...ds which must be observed at all times in order to protect both workers and machine WARNING This symbol refers to safety standards which must be observed carefully in order to guarantee your safety ot...

Page 7: ...been authorised by the Manufacturer especially on safety devices Use of non original spare parts Zhermack S p A cannot as of this moment be held liable if the machine is modified or tampered with wit...

Page 8: ...t must be free from obstacles clean and properly illuminated Take measures to ensure that you are not distracted when using the machine In the event of a malfunction follow the advice given in this ma...

Page 9: ...comply with the instructions in this manual Zhermack S p A is as of this moment exonerated from any liability concerning injury to persons or damage to objects that may result from using this machine...

Page 10: ...hine described in this manual is the elite mix vacuum mixer designed to spatula mix under vacuum conditions dental model plasters coatings and silicones 3 2 1 Description of the components 1 Display 2...

Page 11: ...plate Should the ID plate deteriorate and become illegible even partially order a replacement plate from the manufacturer remember to quote the relevant data A Name and address of manufacturer B Machi...

Page 12: ...iding maximum user safety are an Zhermack S p A constant making our products safe and internationally competitive The elite mix is specifically designed to spatula mix under vacuum conditions dental m...

Page 13: ...XI0991290 4 2 2 Standard accessories Components Quantity Ord Code Stand 1 XR0011510 Lid with spatula 200cc 1 XR0011520 Lid with spatula 1000cc 1 XR0011530 200 cc cup 1 XI0010640 1000 cc cup 1 XI001065...

Page 14: ...t care and attention when mounting the machine Observe all the precautions and instructions contained in the following paragraphs IMPORTANT Always keep the original product packaging throughout the gu...

Page 15: ...perly compiled ID form Failure to observe the above exonerates the Manufacturer from any liability concerning machine malfunction and consequently renders the Warranty null and void If the unit is to...

Page 16: ...or optimum machine operation but must also be well illuminated aired not dusty and not exposed to direct sunlight Note also that the unit must be positioned so the connection plug can be handled manip...

Page 17: ...ways check for proper stability first 6 3 1 Pre use installation WALL MOUNTED WORKBENCH The elite mix has been designed to be wall mounted For fast accurate drilling of the holes use the supplied dril...

Page 18: ...mper with the power lead and its plug When replacing them owing to damage and or wear please contact an Authorised Service Centre A proper earth connection is compulsory Should it temporarily be neces...

Page 19: ...confirm your choice by pressing the dial 6 7 SELECTING THE LANGUAGE AND PRESSURE THRESHOLD Apply the same procedure to change the vacuum threshold Press the FUNCTION 3 key to return to the main menu...

Page 20: ...has been designed for spatula mixing under vacuum conditions of dental model plasters coatings and silicones 6 8 PURPOSE OF THE MACHINE 6 9 IMPROPER AND FORBIDDEN USE Using the machine for any purpos...

Page 21: ...verloads that are anomalous or in any case higher than those given in this manual elite mix mixers also feature a safety fuse designed to protect both machine and operator from overloads CHAPTER 7 USI...

Page 22: ...rotate the dial 2 choose the programme and press the FUNCTION key again 7 3 1 Selecting the programme P06 Abcde 06 time mixing 00 00 P06 Name Program time mixing 00 00 P06 Name Program P06 Aame Progra...

Page 23: ...odification of parameter d2 1 rotate the dial to set the value d2 2 and press again to confirm d2 3 Parameters relative to mixing speed d3 pre mixing d4 pre vacuum time d5 and the rotation inversion i...

Page 24: ...gnetic sensor will detect the presence of the cup lid and start the vacuum pump After just a few seconds the cup will be held in place automatically by the vacuum and the display will show the achieve...

Page 25: ...act the Manufacturer or your Authorised Servicing Centre 12 Figure 15 Fig 15 During mixing in case of unexpected black out rotation will stop and container will be kept connected To preserve good qual...

Page 26: ...ents to clean mixing unit components Eye goggles and a face mask must be worn when using compressed air for cleaning purposes Do not allow any persons near the machine as they could be hit by flying d...

Page 27: ...8 3 UNSCHEDULED MAINTENANCE Modifications which alter the machine characteristics from a safety and risk prevention viewpoint may only be made by the Manufacturer who shall then issue a certificate st...

Page 28: ...information on the equipment ID plate see paragraph 3 3 and explain the problem clearly 3 Fax all the above information and a properly filled out ID Form see Appendix A 2 to 39 0425 53 596 8 4 RESTAR...

Page 29: ...itioning the cup the pressure still hasn t dropped below the threshold 50 a warning appears and the pump is switched off In this case it is necessary to carry out an inspection and trace the problem e...

Page 30: ...MAINTENANCE AND USE MANUAL elite mix EN APPENDICES A 1 CE DECLARATION OF CONFORMITY A 2 WARRANTY CERTIFICATE AND IDENTIFICATION FORM A 4 A 5 Authorized service partners NOTES A 3 MAINTENANCE AND REPAI...

Page 31: ...ces in electrical and electronic equipment It is also in conformity with the laws implementing the following directives EC Directive 2004 108 EC EMC Directive and subsequent amendments EC Directive 20...

Page 32: ...ler the Manufacturer authorised servicing centres or the Manufacturer The Warranty entitles the purchaser to free replacement of defective parts It does not entitle the purchaser to replacement of the...

Page 33: ...131 of 264 MAINTENANCE AND USE MANUAL elite mix EN A 3 MAINTENANCE AND REPAIR WORKSHEET Date Description of Work Signature...

Page 34: ...ite mix EN A 4 A 5 Authorized service partners NOTES Please visit the page http www zhermack com Technical Equipment Authorized_service_partners kl to check all the updated telephone numbers and addre...

Page 35: ......

Page 36: ...Rev 02 14 EN...

Reviews: