CONNECTING UP TO THE POWER SUPPLY
The user must provide a power connection with relative socket near the machine installation
point. The user must also install an adequate electrical circuit breaker upstream from the socket
as well as efficacious overload/indirect contact safety devices. Connection is effected via the
safety plug (16A, in compliance with European standards) at the end of the power lead: this
must be inserted in the mains socket.
When connecting check:
• that mains voltage and frequency are as indicated on the identification plate (incorrect power
supply voltage may damage the machine);
• that the mains supply has a proper, efficient earth connection.
It is forbidden to tamper with the power lead and its plug. When replacing them
owing to damage and/or wear please contact an Authorised Service Centre.
A proper earth connection is compulsory. Should it temporarily be
necessary to use an extension lead the latter must comply with the
standards in force in the country of use.
6.5
STARTING UP THE MACHINE
Figure
1
Fig. 1:
Make the holes with the aid of the supplied
template and position the vacuum mixer correctly on
the wall (or on the workbench if you have a stand);
see section 6.3.1.
6
Figure
2
Fig. 2:
Insert the connector in the socket (
6
) near the
main switch, connect the mixer plug (
9
) to the mains
power socket.
Always observe the information given in section 6.4.
Failure to observe any of the above machine installation instructions may lead
to malfunctions and render the warranty null and void.
7
The examples shown in the following illustrations refer to a wall-mounted
elite mix.
100 mm
100 mm
Ø6 mm
45 mm (min)