121 of 264
MAINTENANCE AND USE MANUAL
elite mix
EN
Figure
10
Fig. 10:
When using the elite mix always select a
recipient of a suitable size and prepare the material
to be mixed.
To obtain a good final result pre-mix
by hand.
time mixing 00:00
time mixing 05:00
time mixing
05:00
P06 Abcde 06
pre-mix time
00
P06 Abcde 06
pre-vac time
00
P06 Abcde 06
reverse time
00
P06 Abcde 06
rpm
350
P06 Abcde 06
time mixing
00:00
P06 Abcde 06
time mixing 00:00
d2
d3
d4
d5
d6
d2.1
d2.2
d2.3
d1
3
2
Figure
9
Fig. 9:
Select the programme and press the dial (
2
).
With the Programme Name flashing against a black
background (
d1
), rotate the dial (
2
) to go to the
“Mixing time” parameter (
d2
); press the dial (
2
) to go
to modification of parameter (
d2.1
): rotate the dial to
set the value (
d2.2
) and press again to
confirm (
d2.3
).
Parameters relative to mixing speed (
d3
), pre-mixing
(
d4
), pre-vacuum time (
d5
) and the rotation inversion
interval (
d6
) can be programmed in a way similar way
to the “Mixing time" example.
Parameter
Description
Range
from to
Unit of
Measure
Step
Default
Notes
Mixing Time
Mixing Duration
00:00 - 05:00
min:sec
1 sec
00:00
.
Mixing Speed
Motor Speed
100 - 450
rpm
10
350
.
Pre-mixing
Time dedicated to
pre-mixing at 100
rpm
0 - 25
sec
5
0
Can be activated or
deactivated (by setting
to 0)
Pre-vacuum time
Time interval from
achievement of
constant in-cup
vacuum to start of
mixing
2 - 60
sec
1
0
Can be activated or
deactivated (by setting
to less than 2)
Inversion interval
Sets time after
which the direction
of spatula rotation
is inverted
2 - 30
sec
1
0
Inversion is
deactivated by setting
to less than 2 seconds
Summary of Contents for elite mix
Page 1: ...User Manual Vacuum mixers IT FR ES HR RU ZH DE EN elite mix...
Page 2: ......
Page 35: ......
Page 36: ...Rev 02 14 EN...