3.6 Additonal functions max-power / zero-power
(I
max
/ I
min
)
Clutch power flow can be influenced irrespective of
operating mode. Zero or max. power for ERM possible
(depends on size of unit connected). Optional limitation of
max. power by MobiDig 200 program.
Application / Use
• Max-power e.g. for emergency stop
• Zero-power e.g. for start-up
Activation of additional functions
Jumper
on ERM board must be in
Pos. 2
.
Pos. 1
must
not
be connected!
(cf. 1.4 Jumper position).
•
Input
for
max-power function: Pin 15
•
Input
for
min-power function
:
Pin 14
•
Ground: Pin 1
or
2
Each function remains
active
as long a signal is present on
input (
low level
, cf. 1.1 Technical data).