Standard Cable Connections
Select the desired mounting locations and drill holes per template.
Run cables between Actuator/Processor and Control Head.
At the Control Head, strip back the PVC cover on the shielded cable approximately 2"
(50mm)
.
Strip and cut off the shielding and drain wire flush with the end of the PVC cover (the
drain wire at the Control Head is not connected to ground).
Strip 3/8"
(9,5mm)
insulation off each wire.
Twist the individual strands of the wires to minimize fraying.
Crimp a locking fork terminal (included with each Control Head) to each of the conduc-
tors.
Make connections to the Control Head as shown above for MicroCommander, ClearCom-
mand, and CruiseCommand Systems.
Hand Held Control is a Station option. Contact your ZF Mathers Dealer for further information
on Hand Held requirements and options.